English (GB)
29
10.5.5 Shaft seal kit
For position numbers, see pages 39 and 40.
For service parts not shown in the above table, consult
www.grundfos.com
WebCAPS, Service.
Examples of service parts:
• Cable
• pump housing
• impeller
• bearings
• shaft/rotor
• clamp
• stator
• motor complete, both standard and Ex.
10.6 Contaminated pumps
If Grundfos is requested to service the pump, Grundfos must be
contacted with details about the pumped liquid, etc.
before
the
pump is returned for service. Otherwise Grundfos can refuse to
accept the pump for service.
Possible costs of returning the pump are to be paid by the
customer.
However, any application for service (no matter to whom it may
be made) must include details about the pumped liquid if the
pump has been used for liquids which are injurious to health or
toxic.
Before a pump is returned, it must be cleaned in the best possible
way before it is returned.
Service instruction and service video can be found on
www.grundfos.com.
Pos.
Description
2-pole:
2.2 - 4.0 kW
6.0 - 11 kW
4-pole:
1.1 - 2.2 kW
3.0 - 7.5 kW
Rubber type:
NBR
NBR
Kit no:
96102360
96102361
105
Shaft seal cartridge
1
1
107
O-ring
110 x 3
1
134.5 x 3
1
1
160 x 3
1
153b
O-ring
17.0 x 2.4
1
28 x 2
1
157
Corrugated spring
1
1
Note
A possible replacement of the cable must be
carried out by Grundfos or a service workshop
authorized by Grundfos.
Note
If a pump has been used for a liquid which is
injurious to health or toxic, the pump will be
classified as contaminated.
Summary of Contents for SL1.100.100.40.4
Page 39: ...Appendix 39 15 Exploded drawings SLV TM04 2777 2605...
Page 40: ...Appendix 40 SL1 TM04 2778 0904...
Page 41: ...41...