6.4 Electrical connection
6.4.1 Electrical connection of the Selcoperm control cabinet
Observe the electrical data. See section
.
Wiring: 5 x 2.5 mm
2
, 3 N + PE
6.4.2 Electrical connection of the brine dosing station
Power supply
Wiring: Minimum 4 x 1.5 mm
2
, 1 phase + N + PE
Analog setpoints
Wiring: Minimum 4 x 0.5 mm
2
, screened
For details on electrical connection of the dosing pumps, see the
separate pump manuals.
Error signal
Wiring: Minimum 4 x 1 mm
2
Emergency stop
Wiring: Minimum 9 x 1 mm
2
with PE
6.4.3 Electrical connection of the degassing and storage tank
Level switch (4.03) for leakage detection
Wiring: Minimum 4 x 0.5 mm
2
Level sensor (4.10)
Wiring: Minimum 3 x 0.5 mm
2
, screened
Overflow switch (4.12)
Wiring: Minimum 2 x 0.5 mm
2
Exhaust air flow sensor (4.13)
Wiring: Minimum 3 x 0.5 mm
2
, screened
NaClO solution line level switch (4.04)
Wiring: Minimum 2 x 0.5 mm
2
Pin assignment:
6.4.4 Electrical connection of degassing fans (EF4.01,
EF4.02)
Power supply
Signal connection
Wiring: Minimum 7 x 1.0 mm
2
with PE
6.4.5 Electrical connection of rectifier (REC)
AC connection
Wiring: 3 PE
DC connection
Wiring from rectifier to Selcoperm electrolyser:
• Minimum two cables of specification:
Tecwind H07BN4-F 1 x 240 mm
2
Wiring from Selcoperm electrolyser back to rectifier:
• Minimum two cables of specification:
Tecwind H07BN4-F 1 x 240 mm
2
Signal connection
Wiring: Minimum 11 x 1.0 mm
2
with PE
6.4.6 Earthing
Establish the earthing according to the separate wiring diagrams
delivered with the system.
Observe the earth connections in the PID in section
and Instrumentation Diagram (PID)
.
WARNING
Electric shock
Death or serious personal injury
- Before making any electrical connections, switch
off the power supply and make sure that it cannot
be accidentally switched on.
- All electrical connections must be carried out by a
qualified electrician in accordance with local
regulations.
- All electrical connections must be carried out in
accordance with the separate wiring diagrams
delivered with the system.
- The electrical connection of components must be
carried out in accordance with the separate
supplier manuals delivered with the system.
Make sure the voltage and frequency of the local
power supply corresponds to the technical
requirements of the system components. See section
.
Install separate fuses with sufficient capacity for all
system components.
This circuit is intrinsically safe. Use a separate cable
duct.
This circuit is intrinsically safe. Use a separate cable
duct.
Extend the cable of the plug as required for the
individual installation.
Description
Colour
Signal
Selcoperm
terminal
Namur+
Brown
+
-XD6.1
Namur-
Blue
-
-XD6.2
Fan type
Wiring
CMVeco 160/160
Minimum 4 x 1.5 mm
2
with PE
CMVeco 200/200
CMVeco 315/315
Minimum 4 x 2.5 mm
2
with PE
Select the line cross-section of the cable and the
fuse rating according to the electrical data of the
rectifier. See section
Use a torque wrench to apply the correct torque to
the bolts. See section
.
WARNING
Electric shock
Death or serious personal injury
- Make sure the protection against accidental
contact is installed correctly before switching on
the power supply of the system.
See fig.
, pos. 1 and fig.
, pos. 1 and 2.
WARNING
Electric shock
Death or serious personal injury
- Make sure all earth connections are established
correctly before switching on the power supply.