1. General information

1.1 Target group

These installation and operating instructions are 
intended for professional as well as non-professional 
users.

1.2 Hazard statements

The symbols and hazard statements below may 
appear in Grundfos installation and operating 
instructions, safety instructions and service 
instructions.

The hazard statements are structured in the 
following way:

1.3 Notes

The symbols and notes below may appear in 
Grundfos installation and operating instructions, 
safety instructions and service instructions.

2. Receiving the product

2.1 Inspecting the product

Check that the product received is in accordance 
with the order.
Check that the voltage and frequency of the product 
match the voltage and frequency of the installation 
site. See section 

6.4.1 Nameplate

.

2.2 Scope of delivery

The box contains the following items:

1 Grundfos SCALA2 pump

1 quick guide

1 safety instructions booklet.

3. Installing the product

3.1 Location

The pump can be installed indoors or outdoors, but it 
must not be exposed to frost.
We recommend that you install the pump near a 
drain or in a drip tray connected to a drain in order to 
lead away possible condensation from cold surfaces.

3.1.1 Minimum space

The pump requires a minimum space of 430 x 215 x 
325 mm (17 x 8.5 x 12.8 inches).
Even though the pump does not require much space, 
we recommend that you leave enough space for 
service and maintenance access.

3.1.2 Installing the product in frosty environment

Protect the pump from freezing if it is to be installed 
outdoors where frost may occur.

DANGER

Indicates a hazardous situation which, if 
not avoided, will result in death or serious 
personal injury.

WARNING

Indicates a hazardous situation which, if 
not avoided, could result in death or 
serious personal injury.

CAUTION

Indicates a hazardous situation which, if 
not avoided, could result in minor or 
moderate personal injury.

SIGNAL WORD

Description of hazard

Consequence of ignoring the warning.
- Action to avoid the hazard.

Observe these instructions for 
explosion-proof products.

A blue or grey circle with a white graphical 
symbol indicates that an action must be 
taken.

A red or grey circle with a diagonal bar, 
possibly with a black graphical symbol, 
indicates that an action must not be taken 
or must be stopped.

If these instructions are not observed, it 
may result in malfunction or damage to the 
equipment.

Tips and advice that make the work easier.

Install the pump in such a way that no 
undesirable collateral damage can arise 
due to leakage.
If the unlikely event of an internal leakage 
occurs, the liquid will be drained through 
the bottom of the pump.

Summary of Contents for SCALA2

Page 1: ...SCALA2 Installation and operating instructions GRUNDFOS INSTRUCTIONS Other languages http net grundfos com qr i 98880508 ...

Page 2: ...2 ...

Page 3: ...3 Table of contents SCALA2 English GB Installation and operating instructions 4 ة العربي AR غيل التش و ب التركي ات تعليم 45 Declaration of conformity 46 ...

Page 4: ...ions 14 7 1 Menu overview SCALA2 14 8 Setting the product 15 8 1 Setting the outlet pressure 15 8 2 Locking and unlocking the operating panel 15 8 3 Expert settings SCALA2 15 8 4 Resetting to factory settings 17 9 Servicing the product 17 9 1 Maintaining the product 17 9 2 Customer service information 18 9 3 Service kits 18 10 Starting up the product after standstill 19 10 1 Deblocking the pump 19...

Page 5: ...space The pump requires a minimum space of 430 x 215 x 325 mm 17 x 8 5 x 12 8 inches Even though the pump does not require much space we recommend that you leave enough space for service and maintenance access 3 1 2 Installing the product in frosty environment Protect the pump from freezing if it is to be installed outdoors where frost may occur DANGER Indicates a hazardous situation which if not ...

Page 6: ...refully screw the inlet and outlet connections to the pipe fittings using a pipe wrench or similar tool Keep the union nut on the pipe fitting if you have removed it from the pump The pump is equipped with flexible connections 5 to facilitate the connection of inlet and outlet pipes 4 Fasten the connections to the inlet and outlet Hold the connection with one hand and tighten the union nut with th...

Page 7: ...ommend to follow the installation examples in sections 3 3 6 to 3 3 8 3 3 6 Mains water pressure boosting Fig 5 Mains water pressure boosting We recommend to use flexible hoses and mount the pump on a vibration damping rubber pad TM06 4321 1915 Rubber pad Pipe hanger for rigid pipe Flexible hose TM06 4347 2015 Pos Description 1 Highest tapping point 2 Pipe hangers and supports 3 Isolating valves 4...

Page 8: ...o protect the pump and installation 6 Foot valve with strainer recommended H1 Maximum suction lift is 8 m 26 ft H2 Inlet pipe must be submersed at least 0 5 m 1 64 ft H2 H1 6 5 4 2 3 1 TM06 4348 4117 Pos Description 1 Highest tapping point 2 Pipe hangers 3 Isolating valve 4 Flexible hoses 5 Drain to sewer 6 Inlet filter If the water may contain sand gravel or other debris please install a filter o...

Page 9: ...nameplate DANGER Electric shock Death or serious personal injury Switch off the power supply before starting any work on the product Make sure that the power supply cannot be accidentally switched on DANGER Electric shock Death or serious personal injury The pump must be earthed The pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock ...

Page 10: ...lectric shock Death or serious personal injury Check that the power plug delivered with the product is in compliance with local regulations Make sure that the pump is connected only to a properly grounded grounding type receptacle protective earthing The protective earth of the power outlet must be connected to the protective earth of the pump The plug must therefore have the same PE connection sy...

Page 11: ... drops per hour may occur When the pump is started up for the first time or when the shaft seal has been replaced a certain run in period is required before the leakage is reduced to an acceptable level The time required for this depends on the operating conditions that is every time the operating conditions change a new run in period will be started Under normal conditions the leaking liquid will...

Page 12: ...bres flammable liquids oil petrol etc aggressive liquids Take care not to drop the pump as it may break Maximum relative humidity during storing 95 RH TM06 3818 1015 Pos Description 1 Air valve for built in pressure tank 2 Operating panel See section 7 Control functions 3 Nameplate See section 6 4 1 Nameplate 4 Plug for access to pump shaft See section 10 1 Deblocking the pump 5 Priming plug See s...

Page 13: ...Psyst max 1MPa NRP XXX XXX XXXXXX PCS XXXXX XX XX 04 6292 2 41 2003 LSPr 022 IDN 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 12 SCALA2 3 45 AKCHDE Type range SCALA2 Rated flow rate 3 m3 h Maximum head 45 m Material code A Standard Supply voltage K 1 x 200 240 V 50 60 Hz M 1 x 208 230 V 60 Hz V 1 x 115 V 60 Hz W 1 x 100 115 V 50 60 Hz Motor C High efficiency motor with frequency converter Mains cable an...

Page 14: ...mp has automatically lowered the pressure See section 4 3 3 Self learning setpoint Fig 15 SCALA2 outlet pressure indication Fig 16 Pressure indication table TM06 3301 5114 SCALA2 Function On off Increases the outlet pressure Decreases the outlet pressure Resets alarms Indicates the required outlet pressure Indicates that the pump has been stopped manually Indicates that the operating panel is lock...

Page 15: ...changed accidentally How to lock the operating panel 1 Hold down the buttons simultaneously for 3 seconds 2 The operating panel is locked when symbol lights up How to unlock the operating panel 1 Hold down the buttons simultaneously for 3 seconds 2 The operating panel is unlocked when symbol turns off 8 3 Expert settings SCALA2 The expert setting menu allows the installer to toggle between the fol...

Page 16: ...ue to operate with the self learning setpoint until the user defined setpoint can be reached Example The user defined pressure is set to 5 bar 72 psi indicated by constant green lights on the pressure indicator panel The pump is unable to reach this pressure due to negative pressure on the inlet side The self learning function automatically adjusts the setpoint to 3 5 bar 51 psi indicated by one f...

Page 17: ...xceeds the running time of 30 minutes the pump will stop after 30 minutes of continuous operation and it will show alarm 6 This alarm will always need to be reset manually 8 4 Resetting to factory settings The pump can be reset to factory setting by pressing the buttons simultaneously for 5 seconds 9 Servicing the product 9 1 Maintaining the product 9 1 1 Insect filter The pump has an insect filte...

Page 18: ...Pull out the inlet non return valve 10 Clean the non return valve with warm water and a soft brush 11 Assemble the components in reverse order To remove the outlet non return valve follow the steps below 1 Turn off the power supply and disconnect the power plug 2 Shut off the water source 3 Open a tap to release the pressure in the pipe system 4 Close the isolating valves and or drain the pipes 5 ...

Page 19: ...tion If the pump is taken out of operation for a period of time for example during the winter it must be disconnected from the power supply and placed in a dry location Proceed as follows 1 Stop the pump by means of the on off button 2 Disconnect the power supply 3 Open a tap to release the pressure in the pipe system 4 Close the isolating valves and or drain the pipes 5 Gradually loosen the primi...

Page 20: ... reset function in the service menu Grundfos Eye Indication Description No lights are on The power is off The pump is not running Two opposite green indicator lights running in the direction of rotation of the pump The power is on The pump is running Two opposite green indicator lights at a 45 angle is the icon used throughout this document for pump running The power is on The pump is running Two ...

Page 21: ... after standstill No d The pump is blocked by impurities See section 10 Starting up the product after standstill Contact Grundfos Service if the problem persists Yes e Dry running Check the water source and prime the pump No f The maximum runtime has been exceeded Check the installation for leakage and reset the alarm No g The internal non return valve is defective or blocked in completely or part...

Page 22: ...p is running at reduced performance Check the cooling conditions Protect the pump against direct sunlight or any nearby heat sources 4 System overpressure Yes a The setpoint is set too high The difference between the outlet pressure and the inlet pressure must not exceed 3 5 bar 51 psi Reduce the pressure to a new setpoint maximum 3 5 bar 51 psi positive inlet pressure Example If the inlet pressur...

Page 23: ...age in the inlet pipe Repair the inlet pipe Yes e Air in the inlet pipe or the pump Prime the inlet pipe and the pump Check the inlet conditions of the pump 6 You can reset the pump but it starts repeatedly immediately after stopping No a The internal non return valve is defective or blocked in completely or partly open position Clean repair or replace the non return valve No b The tank precharge ...

Page 24: ...ontact the nearest Grundfos company or service workshop See also end of life information on www grundfos com product recycling Temperature C F Maximum ambient temperature 1 x 208 230 V 60 Hz 45 113 1 x 115 V 60 Hz 45 113 1 x 200 240 V 50 60 Hz 55 131 Maximum liquid temperature 45 113 Pressure bar psi Maximum system pressure 10 145 Maximum inlet pressure 6 87 Other operating data Maximum head 45 m ...

Page 25: ...أمب تردد ال رتز ھ ة فولتي داد اإلم ت فول وع الن 2 550 2 3 2 8 50 60 1 x 200 240 SCALA2 2 2 2 2 550 2 3 2 8 60 1 x 208 230 SCALA2 2 560 5 5 7 60 1 x 115 SCALA2 ادة وإع واد الم ن م ص التخل ى عل يز الترك ع م ج المنت ذا ھ مم ص واع أن ع جمي ى عل ة التالي ص التخل م قي ق وتنطب دويرھا ت دفوس جرون خات مض SCALA2 الي اإلجم وزن ال ن م ة مئوي بة نس م القي ون تك حيحة ص ة بطريق ه من زاء أج أو ج المنت ذا ھ ن م ص ...

Page 26: ...ب أنب لح أص d ي ف رب تس د يوج دخول ال وب أنب م نع ص افح خة والمض دخول ال وب أنب ر حض خة المض دخل م وال أح e وب أنب ي ف واء ھ خة المض أو دخول ال م نع ير غ مام الص تبدل اس أو لح أص أو ف نظ رجع الم a ير غ مام الص ه ب داخلي ال رجع الم ع وض ي ف الق ع أو ل خل أو ا ً ي كل وح مفت ا ً ي جزئ ال 6 ادة إع ك يمكن خة المض بط ض ل العم دأ تب ا لكنھ رر متك كل بش د بع رة مباش ف التوق زان للخ حن الش بق مس غط الض بط ...

Page 27: ...ب دور ت خة والمض ض منخف م نع بوطة مض ة قيم ى إل غط الض ض بخف م ق دة جدي ى أقص د بح 3 5 ار ب 51 ً ال رط دخول ال غط ض ة مربع ة بوص ل لك ابي اإليج و ھ دخول ال غط ض ان ك إذا ال مث 0 5 ار ب 7 د الح إن ف ة مربع ة بوص ل لك ال أرط و ھ روج الخ غط ض ن م ى األقص 4 ار ب 58 ة مربع ة بوص ل لك ً ال رط a م ت د التحدي ة نقط ة قيم ى عل بطھا ض ب يج الزم ال ن م ى أعل رق الف اوز يتج أال روج الخ غط ض ن بي دخول ال غط وض...

Page 28: ...س انع م ثر تع د ق اإلدارة ال م القس ر انظ 10 د بع ج المنت غيل تش ام الت ف التوق تمرت اس إذا دفوس جرون ة بخدم ل اتص كلة المش d دودة مس خة المض وائب بالش ال خة المض ر وحض اء الم در مص ص افح e اف الج غيل التش م نع د وأع رب تس ن ع ا ً بحث ب التركي ص افح ذار اإلن بط ض f ت وق اوز تج م ت ى األقص غيل التش ال ير غ مام الص تبدل اس أو لح أص أو ف نظ م القس ر انظ رجع الم 9 ج المنت ة خدم g ير غ مام الص ه ب داخل...

Page 29: ... ران أخض ان مبين وءان ض ذار إن ت توقف خة المض ت الوق س نف ي ف ان يومض ابالن متق ران أحم ان مبين وءان ض ذار إن ت توقف خة المض ة األيقون ا ھم ابالن المتق ران األحم ان المبين وءان الض خة المض ف لتوق دليل ال ذا ھ زاء أج ل ك ي ف تخدمة المس ة اآلتي رق الط ن م دة بواح ل عط ن مبي بط ض ادة إع ك يمكن ل العط بط ض ادة إع 1 2 2 12 2 أن خة المض تحاول فس ه نفس اء تلق ن م ل العط زال إذا ة المبين ارة اإلش تختفي وس...

Page 30: ...ي دء ب ل قب ة الطاق داد إم ل افص ن يمك ال ة الطاق داد إم أن ن م د تأك المنتج ب د قص دون غيله تش TM06 4202 1615 خة المض ة إعاق ة إزال 2 2 ش ك ل 22 كل ش ى عل ت الوق ن م ترة لف خة المض غيل تش اف إيق ة حال ي ف در مص ن ع لھا فص ب يج تاء الش ل فص الل خ ال المث بيل س اف ج ان مك ي ف عھا ووض ة بالطاق داد اإلم اآلتي ك ل العم دأ اب غيل التش ن م ج المنت راج إخ 1 1 11 1 ة الطاق داد إم ل افص 5 2 ب األنابي بكة ش...

Page 31: ...حب اس 8 8 رجع الم ير غ دخول ال مام ص حب اس 9 9 ة ناعم اة وفرش ىء داف اء بم رجع الم ير غ مام الص ف نظ 1 0 10 ي عكس ب بترتي ات المكون ب رك 1 1 11 1 5 6 7 8 2 3 4 9 اه أدن وات الخط ع اتب رجع الم ير غ روج الخ مام ص ك لف ات منتج ركز م ر انظ ار الغي ع قط ن ع ات المعلوم ن م د لمزي ى عل دفوس جرون www product selection grundfos com ات منتج ركز م ر انظ ة الخدم م أطق ن ع ات المعلوم ن م د لمزي ى عل دفوس جرون ...

Page 32: ... وف س ح تنج م ل وإذا ائق دق د بع دورة ال ذه ھ رر تتك 24 اعة س دالالت ال ع جمي رى األخ رر المتك ف والتوق غيل التش ع من 8 3 4 8 3 4 ام النظ ي ف رب تس زر ال طة بواس ًا ي دو ي ذارات اإلن ع جمي بط ض ادة إع ب يج ع وض ي ف ية الخاص ذه لھ بة بالنس نع المص بط ض ون يك غيل التش اف إيق كل بش دارت إذا خة المض ف يوق أن ن يمك ت مؤق ي ھ ة الوظيف ذه ھ دة لم ل متواص 30 ة دقيق اف اإليق ع وض ي ف غ يبل ذي ال دوران ال ت...

Page 33: ...دام باس ل لك دايود ال وء ض ئ يض وف س زر ال تخدام باس اف اإليق ا ً ط نش داد اإلع ون يك دما عن داد إع ي اآلل بط الض ادة إع غيل التش ع من رر المتك ف والتوق غيل التش ت وق ى األقص ل المتواص ة قائم ن م روج الخ ير الخب ذاتي ال بط الض ال مث ى عل بوطة مض تخدم المس طة بواس دد المح غط الض ة قيم ون تك ة القيم 5 ار ب 72 ة مبين ون وتك ة مربع ة بوص ل لك ً ال رط غط الض ان بي ة لوح ى عل تمرة مس راء خض واء بأض ا ً ...

Page 34: ...وز تج م ت اق النط ارج خ رارة الح ة درج اف إيق م ت إذا تى ح م المتحك دادات إع خة المض ذكر تت وف س غيلھا تش وال ل تعم ال األزرار أن ني يع ا مم غيل التش ة لوح ل قف ن يمك د قص دون دادات إع أي ير تغي ن يمك غيل التش ة لوح ل قف ة كيفي غيل التش ة لوح ح فت ة كيفي ديل بالتب ب التركي ني لف ير الخب داد إع ة قائم مح تس ة التالي ائف الوظ ن بي ج المنت بط ض 8 8 روج الخ غط ض بط ض 8 1 8 1 غيل التش ة لوح ح وفت ل قف ...

Page 35: ... قيم ذاتي ال بط الض م التحك ائف وظ 7 7 ة للقائم ام الع ر المنظ SCALA2 7 1 7 1 TM06 3301 5114 غيل تش ة لوح SCALA2 1 4 ش ك ل 14 كل ش ة الوظيف SCALA2 إيقاف غيل تش روج الخ غط ض د يزي روج الخ غط ض ل يقل ذارات اإلن بط ض د يعي وب المطل روج الخ غط ض ى عل دل ي ًا ي دو ي ا إيقافھ م ت خة المض أن ى عل دل ي ة مقفل غيل التش ة لوح أن ى عل دل ي غط الض ن مبي SCALA2 7 1 1 7 1 1 TM06 4345 2015 روج خ غط ض ة دالل SCAL...

Page 36: ...X PCS XXXXX XX XX 04 6292 2 41 2003 LSPr 022 IDN 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 12 وع الن اح مفت 6 4 2 6 4 2 E D H C K A 45 3 SCALA2 وع الن اق نط SCALA2 ن المقن دفق الت دل مع م 3 اعة س 3 غط الض ود لعم ى األقص د الح م 45 ادة الم ز رم ار المعي A ة الطاق در مص ة فولتي 240 200 1 ت فول 60 50 رتز ھ K 230 208 1 ت فول 60 رتز ھ M 115 1 ت فول 60 رتز ھ V 115 100 1 ت فول 60 50 رتز ھ W رك المح ردد ت ير...

Page 37: ... 5 م القس ر انظ روج الخ ة فتح 3 3 3 يل توص ب األنابي ام نظ 6 م القس ر انظ دخول ال ة فتح 3 3 3 يل توص ب األنابي ام نظ 7 م القس ر انظ ريغ التف دادة س 6 4 ريف التع 8 ا غمرھ دم ع ب يج ة التھوي وب ثق 9 1 5 6 7 8 2 3 4 9 ة بزاوي ة مرن الت وص ى عل روج والخ دخول ال ا فتحت وي تحت درھا ق 5 ات درج ة أنظم ي ف ذب الع اء الم غط ض ة لتقوي بة مناس خة المض ون تك ة المنزلي اء الم ة تغذي وى محت ن م ى أقص د ح ع م ة ا...

Page 38: ...ن خ أو ئر ب ن م اة المي ع رف 1 0 ش ك ل 10 كل ش غط الض دادات إع ب تتطل 4 5 و 5 0 و 5 5 ار ب 65 و 73 و 80 ب ويج ابي إيج ول دخ غط ض ود وج ة مربع ة بوص ل لك ً ال رط اه المي وب أنب ن م اه المي ع رف د عن ط فق دادات اإلع ذه ھ تخدام اس ي الرئيس ددة المح غط الض ة قيم ى إل ول الوص ن م خة المض ن تتمك م ل إذا ذاتي ال بط الض ية خاص تقوم فس تخدم المس طة بواس م القس ر انظ ي آل كل بش بوطة المض ة القيم ل بتقلي 8 3...

Page 39: ... ائي كھرب ار تي س تالم 3 مم 0 12 ي ف ل األق ى عل ة بوص اب األقط ع جمي غيل التش دء ب ذلك ب ل اكتم ج المنت غيل تش دء ب 4 4 ائل بالس ا امتالئھ ن لحي خة المض غل تش ال خة المض ير تحض 4 1 4 1 ى أدن د بح ب وص ير التحض دادة س ك بف م ق 1 7 تر ل 0 45 كل الش ر انظ خة المض الف غ ي ف اء الم ن م الون ج 9 1 1 رى أخ رة م ير التحض دادة س ط ارب 2 2 اوز يتج حب الس ق عم ان ك إذا 6 م 20 د فق دم ق رة م ن م ثر أك خة الم...

Page 40: ... م د تأك ة بلوح ذكورة الم م القي ع م ان يتوافق ي الرئيس ل المودي ات بيان خطر ة كھربائي دمة ص يرة خط ية شخص ابة إص أو اة الوف ل عم أي دء ب ل قب ة الطاق داد إم ل افص ن يمك ال ة الطاق داد إم أن ن م د تأك المنتج ب د قص دون غيله تش خطر ة كھربائي دمة ص يرة خط ية شخص ابة إص أو اة الوف خة المض أريض ت ب يج ابس وق أريض ت ل بموص زودة م خة المض ذه ھ ر خط ل لتقلي أريض الت وع ن ن م ل وص أن ن م د تأك ة كھربائي د...

Page 41: ...م 26 ًا م د ق H1 ل األق ى عل ا ً ور مغم دخول ال وب أنب ون يك أن ب يج 0 5 تر م 1 64 دم ق H2 H2 H1 6 5 4 2 3 1 ذب ع اء م زان خ ن م حب الس 3 3 8 3 3 8 TM06 4348 4117 ذب ع اء م زان خ ن م حب الس 7 ش ك ل 7 كل ش ف الوص ع الموض نبور ص ب لتركي ة نقط ى أعل 1 ب أنابي ق تعلي روات ع 2 ل فاص مام ص 3 ة مرن راطيم خ 4 اري المج بكة ش ى إل ة بالوع 5 دخول ال ح مرش ى حص أو ل رم ى عل وي يحت أن ن يمك اء الم ان ك إذا ح م...

Page 42: ...ت االھ ص تمت ة مطاطي ة لوح ى عل خة المض TM06 4321 1915 ب التركي ي ف اء الضوض ض خف ة كيفي 4 ش ك ل 4 كل ش ب التركي ة أمثل 3 3 5 3 3 5 ة مطاطي ية حش لب ص وب ألنب وب أنب ق تعلي روة ع رن م خرطوم ي الرئيس ة التغذي ط خ اء م غط ض ة تقوي 3 3 6 3 3 6 TM06 4347 2015 ي الرئيس ة التغذي ط خ اء م غط ض ة تقوي 5 ش ك ل 5 كل ش ف الوص ع الموض نبور ص ب لتركي ة نقط ى أعل 1 ب أنابي اند ومس ق تعلي روات ع 2 لة فاص مامات ص...

Page 43: ...ابي ام نظ غط ض دم ع ن م د تأك دخول ال ذي منف ى عل ل الوص مولتي ص ط وارب ك ف دخول ال ذي منف ف تل د يزي ا ً م دائ د بالي روج والخ ريب تس دوث ح ورة خط ن م روج والخ ذي منف رير لتح د بالي ل الوص مولتي ص إدارة ب م ق كل الش ر انظ روج والخ دخول ال 3 1 1 ربط ال ريط بش ب األنابي ب تركي ع قط ربط ب م ق ي الخيط 2 2 ب تركي ع بقط روج والخ دخول ال لتي وص رص بح ط ارب ة مماثل أداة أو ب أنابي ط رب اح مفت تخدام باس و...

Page 44: ...لجھ أن ن م د تأك م القس ر انظ ب التركي ع موق ردد وت 6 4 1 ل المودي م اس ة لوح ة اآلتي ر العناص ى عل ندوق الص وي يحت ال أن ب يج ن لك ارج الخ أو داخل ال ي ف خة المض ب تركي ن يمك د للتجم رض تتع أو ة بالوع ن م القرب ب خة المض ب ترك أن ب ح ننص ن نح اثف التك ه لتوجي ة ببالوع لة موص ير تقط ينية ص ًا د بعي اردة الب طح األس ن م ل المحتم ى أدن ا ً يز ح خة المض ب تتطل 325 215 430 مم 17 x 8 5 x 12 8 ة بوص ا ف...

Page 45: ...ف وظ 7 35 ة للقائم ام الع ر المنظ SCALA2 7 1 34 ج المنت بط ض 8 34 روج الخ غط ض بط ض 8 1 34 غيل التش ة لوح ح وفت ل قف 8 2 34 ير الخب دادات إع SCALA2 8 3 32 نع المص دادات إع ى عل بط الض ادة إع 8 4 32 ج المنت ة خدم 9 32 ج المنت يانة ص 9 1 31 الء العم ة خدم ات معلوم 9 2 31 ة الخدم م أطق 9 3 30 ام الت ف التوق د بع ج المنت غيل تش 10 30 خة المض ة إعاق ة إزال 10 1 30 غيل التش ن م ج المنت راج إخ 11 29 ج ال...

Page 46: ...0 3 3 2008 EN61800 3 A1 2012 Applies from July 22 2019 RoHS Directives 2011 65 EU and 2015 863 EU Standard used EN 50581 2012 This EU declaration of conformity is only valid when published as part of the Grundfos installation and operating instructions publication number 99468343 0618 Bjerringbro 07 05 2018 Andreas Back Pedersen Senior Manager Grundfos Holding A S Poul Due Jensens Vej 7 8850 Bjerr...

Page 47: ...47 ...

Page 48: ...48 ...

Page 49: ...49 ...

Page 50: ...ro Tlf 45 87 50 50 50 Telefax 45 87 50 51 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti OÜ Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 01360 Vantaa Phone 358 0 207 889 500 France Pompes GRUNDFOS Distribution S A Parc d Activités de Chesnes 57 rue de Malacombe F 38290 St Quentin Fallavier Lyon Tél...

Page 51: ...26 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Leskoškova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa GRUNDFOS PTY LTD Corner Mountjoy and George Allen Roads Wilbart Ext 2 Bedfordview 2008 Phone 27 11 579 4800 Fax 27 11 455 6066 E mail lsmart grundfos com Spain Bombas GRUNDFOS España S A Camino de la Fuentecilla s n E 28110 ...

Page 52: ...68343 0618 ECM 1236000 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding A S ...

Reviews: