6.2 Intended use
The pump is suitable for pressure boosting of fresh water in
domestic water supply systems.
6.3 Pumped liquids
The pump is designed for fresh water with a maximum chloride
content of 300 ppm and a free chlorine content below 1 ppm.
The pump is not suitable for these liquids:
• liquids containing long fibres
• flammable liquids (oil, petrol, etc.)
• aggressive liquids.
6.4 Identification
6.4.1 Nameplate
Fig. 13
Example of nameplate
6.4.2 Type key
This pump has been evaluated for use with water
only.
Only use SCALA2 pumps according to the
specifications stated in these installation and
operating instructions.
If the water can contain sand, gravel or other debris,
there is a risk of pump blockage.
Please install a filter on the inlet side or apply a
floating strainer to protect the pump.
TM0
6
434
0 201
5
Pos. Description
1
Type designation
2
Product number
3
Serial number
4
Production code, year and week
5
Maximum head
6
Minimum head
7
Rated head
8
Rated flow rate
9
Maximum ambient temperature
10
Enclosure class
11
Maximum operation pressure
12
Maximum liquid temperature
13
Minimum and maximum rated power
14
Model
15
Voltage and frequency
16
Approvals
17
Minimum and maximum rated current
DK-8850 Bjerringbro, Denmark
SCALA2 3-45 AKCHDE
Model A
200-240V 50/60Hz
Made in Serbia
P/N 99999999
S/N
P/C 1519
H
max
H
min
H
nom
Q
nom
45 m
16 m
27 m
3 m /h
3
45 C/
55 C
T
amb.max
IPX4D
I(A)
Min.
Max.
P1(W)
0.01
2.8
550
2
T
liq.max
/P
syst.max:
1MPa
NRP XXX-XXX-XXXXXX
PCS XXXXX.XX.XX
04-6292.2.41-2003
LSPr-022-IDN
1
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
12
SCALA2 3 -45 A K C H D E
Type range
SCALA2
Rated flow rate
3:
[m
3
/h]
Maximum head
45: [m]
Material code
A: Standard
Supply voltage
K: 1 x 200-240 V, 50/60 Hz
M: 1 x 208-230 V, 60 Hz
V: 1 x 115 V, 60 Hz
W: 1 x 100-115 V, 50/60 Hz
Motor
C: High-efficiency motor with frequency converter
Mains cable and plug
A: Cable with plug, IEC type I, AS/NZS3112, 2 m
B: Cable with plug, IEC type B, NEMA 5-15P, 6 ft
C: Cable with plug, IEC type E&F, CEE7/7, 2 m
D: Cable without plug, 2 m
G: Cable with plug, IEC type G, BS1363, 2 m
H: Cable with plug, IEC type I, IRAM 2073, 2 m
J:
Cable with plug, NEMA 6-15P, 6 ft
K: Cable with plug, IEC type B, JIS C 8302, 2 m
L:
Cable with plug, IEC type L, CEI 23-16/VII, 2 m
O: Cable with plug, IEC type O, TIS 166-2549, 2 m
Controller
D: Integrated frequency converter
Thread
E: R 1" composite material
F: NPT 1" composite material