background image

English (GB)

8

6.2 Intended use

The pump is suitable for pressure boosting of fresh water in 
domestic water supply systems.

6.3 Pumped liquids

The pump is designed for fresh water with a maximum chloride 
content of 300 ppm and a free chlorine content below 1 ppm.
The pump is not suitable for these liquids:
• liquids containing long fibres
• flammable liquids (oil, petrol, etc.)
• aggressive liquids.

6.4 Identification

6.4.1 Nameplate

Fig. 13

Example of nameplate

6.4.2 Type key

This pump has been evaluated for use with water 
only.
Only use SCALA2 pumps according to the 
specifications stated in these installation and 
operating instructions.

If the water can contain sand, gravel or other debris, 
there is a risk of pump blockage.
Please install a filter on the inlet side or apply a 
floating strainer to protect the pump.

TM0

6

 434

0 201

5

Pos. Description

1

Type designation

2

Product number

3

Serial number

4

Production code, year and week

5

Maximum head

6

Minimum head

7

Rated head

8

Rated flow rate

9

Maximum ambient temperature

10

Enclosure class

11

Maximum operation pressure

12

Maximum liquid temperature

13

Minimum and maximum rated power

14

Model

15

Voltage and frequency

16

Approvals

17

Minimum and maximum rated current

DK-8850 Bjerringbro, Denmark

SCALA2 3-45 AKCHDE

Model  A
200-240V  50/60Hz

Made in Serbia

P/N 99999999

S/N 

P/C 1519

H

max

H

min

H

nom

Q

nom

45 m
16 m
27 m

3 m /h

3

45 C/

55 C

T

amb.max

IPX4D

I(A)

Min.
Max.

P1(W)

0.01

2.8

550

2

T

liq.max

/P

syst.max:

1MPa

NRP XXX-XXX-XXXXXX

PCS XXXXX.XX.XX

04-6292.2.41-2003
LSPr-022-IDN

1

2

3
4

5

6

7

8

9
10

11

13

14

15

16

17

12

SCALA2 3 -45 A K C H D E

Type range
SCALA2
Rated flow rate
3:

[m

3

/h]

Maximum head
45: [m]
Material code
A: Standard
Supply voltage
K: 1 x 200-240 V, 50/60 Hz
M: 1 x 208-230 V, 60 Hz
V: 1 x 115 V, 60 Hz
W: 1 x 100-115 V, 50/60 Hz
Motor
C: High-efficiency motor with frequency converter
Mains cable and plug
A: Cable with plug, IEC type I, AS/NZS3112, 2 m
B: Cable with plug, IEC type B, NEMA 5-15P, 6 ft
C: Cable with plug, IEC type E&F, CEE7/7, 2 m
D: Cable without plug, 2 m
G:  Cable with plug, IEC type G, BS1363, 2 m
H: Cable with plug, IEC type I, IRAM 2073, 2 m
J:

Cable with plug, NEMA 6-15P, 6 ft

K: Cable with plug, IEC type B, JIS C 8302, 2 m
L:

Cable with plug, IEC type L, CEI 23-16/VII, 2 m

O: Cable with plug, IEC type O, TIS 166-2549, 2 m
Controller
D: Integrated frequency converter
Thread
E: R 1" composite material
F: NPT 1" composite material

Summary of Contents for SCALA Series

Page 1: ...SCALA Installation and operating instructions GRUNDFOS INSTRUCTIONS http waterheatertimer org Water heater recirculation system html...

Page 2: ...9 8 Setting the product 10 8 1 Setting the outlet pressure 10 8 2 Locking and unlocking the operating panel 10 8 3 Expert settings SCALA2 10 8 4 Resetting to factory settings 11 9 Servicing the produ...

Page 3: ...1 25 bar 18 psi In case of suction lift of more than six metres the pipe resistance on the outlet side must be at least two metres water column or 3 psi at any given flow in order to obtain optimum op...

Page 4: ...f the flexible hose Fig 4 How to reduce noise in the installation 3 3 5 Installation examples Fittings hoses and valves are not supplied with the pump We recommend to follow the installation examples...

Page 5: ...ction lift is 8 m 26 ft H2 Inlet pipe must be submersed at least 0 5 m 1 64 ft TM06 4348 4117 Pos Description 1 Highest tapping point 2 Pipe hangers 3 Isolating valve 4 Flexible hoses 5 Drain to sewer...

Page 6: ...ertain that the pump is connected only to a properly grounded grounding type receptacle protective earthing If national legislation requires a Residual Current Device RCD a Ground Fault Circuit Interr...

Page 7: ...ent of an internal leakage occurs the liquid will be drained through the bottom of the pump Install the pump in such a way that no undesirable collateral damage can arise 5 Handling and storing the pr...

Page 8: ...temperature 13 Minimum and maximum rated power 14 Model 15 Voltage and frequency 16 Approvals 17 Minimum and maximum rated current DK 8850 Bjerringbro Denmark SCALA2 3 45 AKCHDE Model A 200 240V 50 60...

Page 9: ...e cause has disappeared or been remedied See section 8 3 3 Auto reset For further information about system status see section 12 Fault finding the product TM06 3301 5114 SCALA2 Function On off Increas...

Page 10: ...tpoint The pump will lower the setpoint to either 4 5 3 5 or 2 5 bar 65 51 or 36 psi The self learned setpoint is indicated on the operating panel by one flashing green light After every 24 hours the...

Page 11: ...bottom and can easily be removed and cleaned with a stiff brush See fig 19 Clean the insect filter once a year or as needed Fig 19 Insect filter 9 1 2 Inlet and outlet valves The pump is maintenance f...

Page 12: ...uct 4 The pump will remember the controller settings even if it is turned off 10 1 Deblocking the pump The end cover incorporates a plug which can be removed by means of a suitable tool This makes it...

Page 13: ...reset function in the service menu Grundfos Eye Indication Description No lights are on The power is off The pump is not running Two opposite green indicator lights running in the direction of rotatio...

Page 14: ...completely or partly open position Clean repair or replace the non return valve See section 9 Servicing the product 2 The pump is running a Leakage from the pipe system or the non return valve is not...

Page 15: ...ump but it runs only for a few seconds Yes a Dry running or water shortage Check the water source and prime the pump Yes b The inlet pipe is blocked by impurities Clean the inlet pipe Yes c The foot o...