8. Setting the product
The pump will remember the controller settings even if it is turned
off.
8.1 Setting the outlet pressure
Adjust the outlet pressure by pressing
.
8.2 Locking and unlocking the operating panel
The operating panel can be locked, which means that the buttons
do not function and no settings can be changed accidentally.
How to lock the operating panel
1. Hold down the
buttons simultaneously for 3 seconds.
2. The operating panel is locked when
symbol lights up.
How to unlock the operating panel
1. Hold down the
buttons simultaneously for 3 seconds.
2. The operating panel is unlocked when
symbol turns off.
8.3 Expert settings, SCALA2
The expert setting menu allows the installer to toggle between the
following functions:
• self-learning
• auto reset
• anti cycling
• maximum continuous operating time.
8.3.1 Accessing the expert settings
Proceed as follows:
1. Hold down the
button for 5 seconds.
2. The
symbol will start flashing to indicate that the expert
settings are active.
The pressure indicator now acts as the expert menu. A flashing
green diode is the cursor. Move the cursor using the
buttons, and toggle the selection on or off using the
button.
The diode for each setting will light up when the setting is active.
Fig. 17
Expert menu overview
8.3.2 Self-learning function
The factory setting for this function is "on".
On
If the pump cannot reach the user-defined pressure setpoint, the
self-learning function will automatically adjust the setpoint.
The pump will lower the setpoint to either 4.5, 3.5 or 2.5 bar (65,
51 or 36 psi).
The self-learned setpoint is indicated on the operating panel by
one flashing green light.
After every 24 hours, the pump will automatically attempt to revert
to the original user-defined setpoint. If this is not possible, the
pump will again return to the self-learned setpoint. The pump will
continue to operate with the self-learning setpoint, until the
user-defined setpoint can be reached.
Example:
The user-defined pressure is set to 5 bar (72 psi), indicated by
constant green lights on the pressure indicator panel.
The pump is unable to reach this pressure due to negative
pressure on the inlet side.
The self-learning function automatically adjusts the setpoint to 3.5
bar (51 psi), indicated by one flashing green light on the pressure
indicator panel.
After 24 hours, the pump will automatically try to adjust the
setpoint back to 5 bar (72 psi).
Fig. 18
User-defined setpoint (left) and self-learned setpoint
(right)
How to reset the self-learned setpoint
1. You can manually reset the settings by pressing any button on
the operating panel. The pump will immediately try to reach
the original setpoint.
2. If the pump keeps reducing the setpoint due to self-learning,
we recommend to reduce the setpoint manually on the
operating panel.
Off
If you set the self-learning function to off and the pump is unable
to reach the desired setpoint, the pump will show alarm 5.
Expert settings are for installers only.
Move cursor up.
Move cursor down.
Toggle settings.
TM
06
43
46
41
1
7
Auto reset
Anti cycling
Maximum continuous
operating time
Exit expert menu
Self-learning
TM
07
00
78
41
1
7
TM
07
00
79
41
1
7