En
gl
is
h (
G
B)
14
9.3 Electrical data
9.3.1 Speed
9.4 Dimensions
Fig. 11
SB pump. same dimensions with
integrated inlet strainer and with floating
inlet strainer
Fig. 12
SBA pump. same dimensions with
integrated inlet strainer and with floating
inlet strainer
SB
Voltage
[V]
Frequency
[Hz]
P1
P2
I
1/1
[A]
[kW]
[hp]
3-25
1 x 230
50
0.57
0.52
2.8
3-35
0.80
0.72
3.8
3-45
1.05
0.83
4.8
3-25
1 x 115
60
0.70
0.50
5.5
3-35
0.90
0.75
8.4
3-45
1.10
1.00
9.8
3-25
1 x 230
0.57
0.50
2.5
3-35
0.73
0.75
3.3
3-45
0.92
1.00
4.2
SBA
Voltage
[V]
Frequency
[Hz]
P1
P2
I
1/1
[A]
[kW]
[hp]
3-35
1 x 230
50
0.80
0.72
3.8
3-45
1.05
0.83
4.8
3-35
1 x 115
60
0.80
0.75
8.4
3-45
1.05
1.00
9.8
3-35
1 x 230
0.74
0.75
3.4
3-45
0.90
1.00
4.1
SB
HF
Voltage
[V]
Frequency
[Hz]
P1
P2
I
1/1
[A]
[kW]
[hp]
5-55
1 x 230
50
1.70
1.36
7.0
5-70
2.00
1.60
9.1
5-50
1 x 230
60
1.67
1.36
7.6
5-65
2.07
1.63
9.4
Speed
50 Hz
[min
-1
]
60 Hz
[min
-1
]
SB
2800
3400
SBA
2800
3400
SB HF
2800
3360
TM
04
62
43
51
09
TM
05
4
804
27
12
NPT / G 3/4
NPT / G 1
*
*