After the pump, has been operating for a sufficient length of time to bring it up to operating tem-
peratures, the final alignment should be checked. Once the pump has reached operating temperature,
stop the pump, lock out the power source, and immediately remove coupling guard. Disconnect
coupling and check the alignment. Make any necessary adjustments at this time. Reconnect
coupling and replace coupling guard.
NEVER RUN PUMP WITHOUT THE COUPLING GUARD. DISREGARD OF THIS WARNING CAN
RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
(F) Pump Shutdown: Slowly close discharge valve and shut off power to the motor. Lock out motor power
supply to prevent accidental restart when performing inspection or routine maintenance.