2.2 Electrical data
2.2.1 Power consumption
2.2.2 IP codes
2.3 Delivery state
The compact chlorine dioxide system comprises:
• The preparation system, completely assembled and wired up,
on a PP supporting frame, including dosing pumps and suction
lines.
• Dosing controller for flow monitoring of hydrochloric acid and
sodium chlorite.
• Tank-level monitor and empty indication for hydrochloric acid
and sodium chlorite.
• Chlorine dioxide reactor.
• Bypass system with flowmeter and solenoid valve,
or optionally
– circulating pump and flowmeter,
– solenoid valve, dosing ball valve and flowmeter.
• Static mixer.
• Control electronics, directly mounted on the supporting frame,
and wired up.
• Optional exhaust device: Injector with solenoid valve,
electrically connected to the control electronics,
supporting frame with side parts.
Max. permissible load of
potential-free output contacts
250 V, 6 A, max. 550 VA
Analog input
0/4-20 mA, load: 50
Ω
Analog output
0/4-20 mA, load: max. 500
Ω
Contact input
max. 50 contacts/second
Max. permissible mains
impedance with 90 Watt
bypass
0.168 + j 0.168)
Ω
, (testing
according to EN 61000-3-11)
Max. permissible mains
impedance with 340 Watt
bypass
0.059 + j 0.059)
Ω
, (testing
according to EN 61000-3-11)
OCD-164
Power consumption [VA]
-30 to -220
300
-350 to -2000
650
Component
IP code
Electronics, dosing pumps, solenoid valve,
flowmeter
IP65
Bypass pump
IP44
Dosing controller
IP67
Summary of Contents for Oxiperm OCD-164
Page 2: ...2...
Page 247: ...Fran ais FR 247 4 crou filtre PVC gris...
Page 422: ...RU 422 10 10...
Page 431: ...RU 431 10 5 5 2 1 5 5 6 5 6 1 5 6 1 TM04 8202 4510 50 60 6 20 11 1D O2 O...
Page 432: ...RU 432 5 6 2 1 2 3 20 20 4 11 4 5 4 4 5 4 6 5 6 5 6 TM04 8203 4510 1 20 2 3 4 5 6...
Page 526: ...526...