8
CONTENTS
Page
General information
Delivery and handling
Delivery
Handling
Type keys
Type NB
Type NBG
Impeller diameter
Pumped liquids
Technical data
Ambient temperature
Liquid temperature
Operating pressure
Min. inlet pressure
Maximum inlet pressure
Minimum flow rate
Maximum flow rate
Electrical data
Weight
Sound level
Pump speed relative to material and size
Pump without motor
Motor without feet
Motor with feet
Installation
Preparations before installation
Pump location
Connection
Foundation
Vibration dampening
Expansion joints
Vibration dampers
Direct mounting in pipework
Pipework
Bypass
Measuring instruments
Flange forces and moments
Electrical connection
Motor protection
Frequency converter operation
Start-up
General information
Priming
Checking the direction of rotation
Start-up
Start/stop
Maintenance
Pump
Mechanical shaft seals
Motor 21
Lubrication
10.4.1 Bearing grease
Periods of inactivity and frost protection
Service
Service kits
Calculation of minimum inlet pressure
Fault finding chart
Disposal
1. General information
Pump type and model are stated on the pump nameplate.
The pumps are fitted with Grundfos motors, type MG or MMG. If
the pump is fitted with a motor make other than Grundfos, please
note that the motor data may differ from the data stated in this
booklet. This may also influence the pump performance.
2. Delivery and handling
2.1 Delivery
The pumps are tested 100% before leaving the factory. The test
includes a function test where the pump performance is meas-
ured to ensure that the pump meets requirements of relevant
standards. Test certificates are available from Grundfos.
The pumps are delivered from the factory in a carton with a
wooden bottom designed for transport by equipment such as a
forklift truck.
Pump motors as from 4 kW are supplied with lifting eyes.
2.2 Handling
Pumps fitted with motors should be lifted by means of nylon
straps and shackles, if required. See fig. 1.
Fig. 1
Correct lifting of pump
Fig. 2
Incorrect lifting of pump
Prior to installation, read these installation and oper-
ating instructions. Installation and operation must
comply with local regulations and accepted codes of
good practice.
Pump motors as from 4 kW are supplied with lifting
eyes which must not be used for lifting the entire
pump unit. See fig. 2.