3.2.1 Terminal box positions
The terminal box can be turned to another position.
Fig. 2
Terminal box positions (top view)
Proceed as follows:
1. Remove the bolts securing the motor to the
pump.
2. Turn the motor to the required position.
3. Refit and tighten the bolts securing the motor to
the pump.
3.3 Electrical connection
The electric motor must be connected to the supply
as shown in the diagram inside the terminal box
cover.
The pump must be earthed. The electrical
connection must be carried out in accordance with
local regulations.
The operating voltage and frequency are marked on
the pump nameplate. Make sure that the motor is
suitable for the power supply on which it will be used.
4. Starting up the product
The pump can be started against an open or a
closed outlet valve.
Before starting the pump:
•
Make sure that all pipe connections are tight.
•
Make sure that the pump is immersed to the
recommended level.
•
Make sure that chip trays are not blocked by
impurities.
Start the pump as follows
1. See the correct direction of rotation of the pump
on the motor fan cover or on the sight glass.
When seen from the top, the pump must rotate
counterclockwise.
2. Start the pump and check the direction of
rotation.
Fig. 3
Motor fan cover with indication of the
correct direction of rotation
T
M
06
81
53
12
16
DANGER
Electric shock
Death or serious personal injury
- Before starting any work on the product,
make sure that the power supply has
been switched off and that it cannot be
accidentally switched on.
We do not recommend operation via
frequency converter.
The motor must be connected to a motor-
protective circuit breaker.
WARNING
Rotating shaft
Death or serious personal injury
- Be sure that the coupling guard is in
place before starting the pump.
CAUTION
Hot surface
Minor or moderate personal injury
- Make sure that persons cannot
accidentally come into contact with the
hot surface.