En
gl
is
h (
G
B)
6
Lifting with double wire
Fig. 7
KPL and KWM: lifting with double wire,
step 1
Fig. 8
KPL and KWM: lifting with double wire,
step 2
Fig. 9
KPG: lifting with double wire, step 1
Fig. 10
KPG: lifting with double wire, step 2
3.3 Mechanical installation of KPL and
KWM
Observe the maximum cable bending radius, see
11.2.1 Bending radius of cables
Prior to installation, check the oil level in the oil
chamber. See section
Take particular care when installing the pumps, as
the procedure is not similar to that of other
submersible pumps. Make sure that the pump is
aligned with the anti-rotation brackets and in such a
way that pump rotation is prevented when the
impeller is running.
3.3.1 Requirement for free space below the pump
Measure the column pipe diameter,
∅
D, and find the
minimum value for free space below the pump (Min.
C) in the following table. See fig.
and fig.
TM
0
5
9
208
3
313
TM
05
92
08
33
13
TM
07
46
87
221
9
T
M
07
4
6
8
8
22
19
DANGER
Electric shock
Death or serious personal injury
- Before beginning the installation, switch
off the power supply and lock the main
switch in position 0/Off.
- Before working on the pump, switch off
any external voltage connected to the
pump.
Observe all safety regulations at the
installation site, for instance the use of
blowers for fresh-air supply to the pit.
KPL
KWM
∅
D
[DN]
Min. C
[mm]
∅
D
[DN]
Min. C
[mm]
500
250
600
300
600
300
700
350
650
325
800
400
700
350
900
450
800
400
1000
500
900
450
1200
600
1000
500
1400
700
1200
600
1600
800
1400
700
-
-
1500
750
-
-
1600
800
-
-
1800
900
-
-