6. Fault finding the product

DANGER

Electric shock

Death or serious personal injury
- Switch off the power supply before 

starting any work on the product. Make 
sure that the power supply cannot be 
accidentally switched on.

Fault

Cause

Remedy

1.

The pump does 
not run.

a)

The power supply is switched off.

Switch on the power supply.

b)

The fuses in the installation are blown.

Replace the defective fuses.

c)

The pump thermal switch has tripped. 
See section 

3.3 Thermal protection

. See 

also point 2.

The thermal switch restarts the pump 
when the motor has cooled down to 
normal temperature.

2.

The pump stops 
after a short 
time of 
operation (the 
thermal switch 
has tripped).

a)

The temperature of the pumped liquid is 
higher than that stated in section 

7. Technical data

. The motor is 

overheated.

The pump starts automatically after 
sufficient cooling. 

b)

The pump is partly or fully blocked by 
impurities.

Clean the pump.

c)

The water level is too low when the 
pump is started. The pump cannot self-
prime. See sections 

7. Technical data

.

Move the pump to a position with 
higher water level, or add water until 
the pump starts sucking. 

3.

The pump runs 
but gives 
insufficient 
water.

a)

The pump is partly blocked by impurities.  Clean the pump.

b)

The outlet pipe or hose is partly blocked 
by impurities. The hose may be sharply 
bent.

Check and clean the non-return valve, 
if fitted. Straighten out the hose.

4.

The pump runs 
but gives no 
water.

a)

The pump is blocked by impurities. 

Clean the pump. 

b)

The non-return valve in the outlet pipe or 
hose is blocked in closed position or 
blocked by impurities. The hose may be 
sharply bent.

Check the non-return valve.
Clean or replace the valve, if 
necessary. Straighten out the hose. 

c)

Pumps with float switch: The pump does 
not stop because the free cable length of 
the float switch is too long.

Reduce the free cable length.

Summary of Contents for KPC 24/7

Page 1: ...KPC KPC 24 7 Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...the product 7 7 Technical data 8 7 1 Operating conditions 8 7 2 Electrical data 8 7 3 Mechanical data 8 7 4 Dimensions and weights 8 8 Disposing of the product 8 Read this document and the quick guide...

Page 3: ...y circle with a white graphical symbol indicates that an action must be taken If these instructions are not observed it may result in malfunction or damage to the equipment Tips and advice that make t...

Page 4: ...ead Fig 4 Lifting the pump 2 2 3 Positioning the product The pump can be tilted up to 15 from vertical position During operation the pump must be covered by the pumped liquid to ensure efficient cooli...

Page 5: ...t out When the motor has cooled to normal temperature it will restart automatically Carry out the electrical connection according to local regulations DANGER Electric shock Death or serious personal i...

Page 6: ...to fountains and water falls The KPC 24 7 pumps are suitable for portable use in emergency situations such as for drawing water from tanks or rivers for draining swimming pools fountains excavations...

Page 7: ...y after sufficient cooling b The pump is partly or fully blocked by impurities Clean the pump c The water level is too low when the pump is started The pump cannot self prime See sections 7 Technical...

Page 8: ...also end of life information at www grundfos com product recycling Pump type Max head m Max flow rate m3 h KPC 24 7 210 6 5 10 KPC 24 7 270 6 5 12 KPC 300 A 6 5 12 KPC 600 A 10 2 16 Maximum ambient t...

Page 9: ...Dimensions of KPC 24 7 210 and 270 TM02 8466 1713 Pump type Weight kg Dimensions mm Height H Width B Width E KPC 300 A 4 6 275 140 82 KPC 600 A 6 7 376 160 90 H1 H H2 E B A D Stop Start TM06 3861 101...

Page 10: ...1 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 013...

Page 11: ...hona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa Grundf...

Page 12: ...054 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 G...

Reviews: