CONTENTS

Page

1. General information

1.1 Symbols used in this document

1.1.1 Warnings against hazards involving risk of 

death or personal injury

The text accompanying the three hazard symbols 
DANGER, WARNING and CAUTION is structured in 
the following way:

1.

General information

2

1.1 Symbols used in this document

2

2.

Installing the product

3

2.1 Location

3

2.2 Mechanical installation

4

2.3 Electrical connection

5

3.

Starting up the product

5

3.1 Manual operation

5

3.2 Automatic operation with float switch

5

3.3 Thermal protection

5

4.

Product introduction

6

4.1 Product description

6

4.2 Intended use

6

4.3 Pumped liquids

6

5.

Servicing the product

6

5.1 Maintaining the product

6

6.

Fault finding the product

7

7.

Technical data

8

7.1 Operating conditions

8

7.2 Electrical data

8

7.3 Mechanical data

8

7.4 Dimensions and weights

8

8.

Disposing of the product

8

Read this document and the quick guide 
before installing the product. Installation 
and operation must comply with local 
regulations and accepted codes of good 
practice.

This appliance can be used by children 
aged from 8 years and above and by 
persons with reduced physical, sensory or 
mental capabilities or lack of experience 
and knowledge if they have been given 
supervision or instruction concerning use 
of the appliance in a safe way and 
understand the hazards involved.
Children shall not play with the appliance. 
Cleaning and user maintenance shall not 
be made by children without supervision.

Make sure that the system in which the 
pump is incorporated is designed for the 
maximum pump pressure.

This pump has been evaluated for use with 
water only.

DANGER

Indicates a hazardous situation which, if 
not avoided, will result in death or serious 
personal injury.

WARNING

Indicates a hazardous situation which, if 
not avoided, could result in death or 
serious personal injury.

CAUTION

Indicates a hazardous situation which, if 
not avoided, could result in minor or 
moderate personal injury.

SIGNAL WORD

Description of hazard

Consequence of ignoring the warning.
- Action to avoid the hazard.

Summary of Contents for KPC 24/7

Page 1: ...KPC KPC 24 7 Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...the product 7 7 Technical data 8 7 1 Operating conditions 8 7 2 Electrical data 8 7 3 Mechanical data 8 7 4 Dimensions and weights 8 8 Disposing of the product 8 Read this document and the quick guide...

Page 3: ...y circle with a white graphical symbol indicates that an action must be taken If these instructions are not observed it may result in malfunction or damage to the equipment Tips and advice that make t...

Page 4: ...ead Fig 4 Lifting the pump 2 2 3 Positioning the product The pump can be tilted up to 15 from vertical position During operation the pump must be covered by the pumped liquid to ensure efficient cooli...

Page 5: ...t out When the motor has cooled to normal temperature it will restart automatically Carry out the electrical connection according to local regulations DANGER Electric shock Death or serious personal i...

Page 6: ...to fountains and water falls The KPC 24 7 pumps are suitable for portable use in emergency situations such as for drawing water from tanks or rivers for draining swimming pools fountains excavations...

Page 7: ...y after sufficient cooling b The pump is partly or fully blocked by impurities Clean the pump c The water level is too low when the pump is started The pump cannot self prime See sections 7 Technical...

Page 8: ...also end of life information at www grundfos com product recycling Pump type Max head m Max flow rate m3 h KPC 24 7 210 6 5 10 KPC 24 7 270 6 5 12 KPC 300 A 6 5 12 KPC 600 A 10 2 16 Maximum ambient t...

Page 9: ...Dimensions of KPC 24 7 210 and 270 TM02 8466 1713 Pump type Weight kg Dimensions mm Height H Width B Width E KPC 300 A 4 6 275 140 82 KPC 600 A 6 7 376 160 90 H1 H H2 E B A D Stop Start TM06 3861 101...

Page 10: ...1 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 013...

Page 11: ...hona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa Grundf...

Page 12: ...054 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 G...

Reviews: