![Grundfos IO 113 Installation And Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/grundfos/io-113/io-113_installation-and-operating-instructions-manual_2271230025.webp)
English (GB)
25
10. Calibration
After an oil change, the measurement of water in the
oil must be calibrated for the new oil:
1. Let the pump run for at least one minute.
2. Press the reset button for more than five
seconds.
3. 4 mA can now be read between terminals A1 and
G1 of analog output 1. See fig.
(4 mA = 0 %).
11. Maintenance and service
IO 113 cannot be serviced, nor does it need
maintenance. If the module is faulty, it must be
replaced.
12. Disposing of the product
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
The crossed-out wheelie bin symbol on
a product means that it must be
disposed of separately from household
waste. When a product marked with this
symbol reaches its end of life, take it to a
collection point designated by the local
waste disposal authorities. The separate collection
and recycling of such products will help protect the
environment and human health.
You can look up your product on:
www.grundfos.com/products/product-sustainability/
product-recycling.html
If this is done with used oil, the
measurement of water in the oil may be
incorrect.