Fault finding 

8.1

 

Fault codes and remedies 

Fault 

Code 

Fault type 

Possible cause 

Remedy 

OV1 

 
Overvoltage when 
acceleration 
 

1.

 

The input voltage is 
abnormal. 

2.

 

There is large energy 
feedback. 

3.

 

No brake components. 

4.

 

Braking energy is not open. 

 

1.

 

Check the input power. 

2.

 

Check if the DEC time of the load is too short or the pump 
controller starts during the rotation of the motor or it needs 
to increase the energy consumption components. 

3.

 

Install the brake components. 

4.

 

Check the setting of related function codes. 
 

OV2 

 
Overvoltage when 
deceleration 
 

OV3 

 
Overvoltage when 
constant speed running 
 

OC1 

 
Overcurrent when 
acceleration 
 

 

1.

 

The acceleration or 
deceleration is too fast. 

2.

 

The voltage of the grid is too 
low. 

3.

 

The power of the inverter is 
too low. 

4.

 

The load transients or is 
abnormal. 

5.

 

The grounding is short 
circuited, or the output is 
phase loss. 

6.

 

There is strong external 
interference. 

7.

 

The overvoltage stalls 

8.

 

protection is not open. 
 

1.

 

Increase the ACC time. 

2.

 

Check the input power. 

3.

 

Select the pump controller with a larger power. 

4.

 

Check if the load is short circuited (the grounding short 
circuited or the wire short circuited) or the rotation is not 
smooth. 

5.

 

Check the output configuration. 

6.

 

Check if there is strong interference. 

7.

 

Check the setting of related function codes. 

OC2 

 
Overcurrent when 
deceleration 
 

OC3 

Overcurrent when 
constant speed running 

UV 

Bus undervoltage 

 

1.

 

The voltage of the power 
supply is too low. 

2.

 

The overvoltage stalls 

3.

 

protection is not open. 
 

1.

 

Check the input power of the supply line. 

2.

 

Check the setting of related function codes. 

OL1 

Motor overload 

 

1.

 

The voltage of the power 
supply is too low. 

2.

 

The motor setting rated 
current is incorrect. 

3.

 

The motor stall or load 
transients are too strong. 
 

1.

 

Check the power of the supply line. 

2.

 

Reset the rated current of the motor. 

3.

 

Check the load and adjust the torque lift. 

OL2 

Inverter overload 

 

1.

 

The acceleration is too fast. 

2.

 

The rotating motor is reset. 

3.

 

The voltage of the power 
supply is too low. 

4.

 

The load is too heavy. 

5.

 

The motor power is too 
small. 
 

1.

 

Increase the ACC time. 

2.

 

Avoid the restarting after stopping. 

3.

 

Check the power of the supply line. 

4.

 

Select an pump controller with bigger power. 

5.

 

Select a proper motor. 

SPI 

Input phase loss 

 
Phase loss or fluctuation of 
input R, S, T 
 

1.

 

Check input power. 

2.

 

Check installation distribution. 

SPO 

Output phase loss 

 
U, V, W phase loss output (or 
serious asymmetrical three 
phase of the load) 
 

1.

 

Check the output distribution. 

2.

 

Check the motor and cable. 

OH1 

 

Rectifier overheat 
 

1.

 

Air duct jam or fan damage 

2.

 

Ambient temperature is too 
high. 

3.

 

The time of overload running 
is too long. 

1.

 

Dredge the wind channel or change the fan. 

2.

 

Decrease the environment temperature. 

  

OH2 

IGBT overheat 

Summary of Contents for GI SPC 03 65 10

Page 1: ...GRUNDFOS INSTRUCTION GI SPC Solar Pump Controller Electrical installation and operating instruction...

Page 2: ......

Page 3: ...terminals 10 5 4 4 Electrical wiring 10 AC input and output connections 10 DC input connections 10 Communication cable connections 11 6 Keypad Operation Procedure 12 6 1 Keypad introduction 12 6 2 Key...

Page 4: ...uctions are not observed it may result in malfunction or damage to the equipment Notes or instructions that make the job easier and ensure safe operation Warning If these instructions are not observed...

Page 5: ...cted either AC grid power or DC solar Power and the Output of the solar pump controller GI SPC is connected to the Submersible pump It is responsibility of the end user to provide the correct power su...

Page 6: ...t mm Model H1 mm W1 mm D mm H2 mm W2 mm Installation hole GI SPC 03 65 10 280 300 137 131 195 8 Fig 4 Dimension for GI SPC 03 65 10 GI SPC 7 5 65 10 Unit mm Model H1 mm W1 mm D mm H2 mm W2 mm Installa...

Page 7: ...nt Temperature C 60 60 Max Relative Humidity 95 95 Communication RS 485 Enclosure class IP65 4 2 1 Low Voltage Range 3 x 230 V Power KW Power HP Product Model Electrical Data Weight Kg Max P2 KW Rated...

Page 8: ...onnector 1 1 AC connector 1 2 1 2 Keypad 1 1 Network cable 1 1 5 1 Installation Example Fig 5 Installation example showing the required clearance for mounting the product The environment temperature i...

Page 9: ...circuit wiring The COM interfaces are the control circuit interfaces including one 485 communication channel and three digital input channels Figure 10 shows the wiring For interface definitions and s...

Page 10: ...damage For models of choke consult Grundfos Connect the DC output AC input AC output and the communication wire to the males and then plug them to the females of the inverter Tighten up to ensure the...

Page 11: ...in place is heard Tighten the nut in a opposite direction Fig 23 Connector assembly Communication cable connections Follow the below steps for the connecting communication cable Plug the cable into t...

Page 12: ...LED OFF The pump controller is in the keypad operation state LED Blinking The pump controller is in the terminal s operation state LED ON The pump controller is in the remote communication control sta...

Page 13: ...lected parameter from left to right 6 2 2 Running state parameter display After receiving a valid running command the pump controller enters the running state and the keypad displays the running state...

Page 14: ...staying at the current function code Under the third level menu if the parameter is not blinking it means the function code cannot be modify The possible reasons could be This function code is not mod...

Page 15: ...e multi function key QUICK JOG to FWD REVC shifting function P07 02 3 to change the running direction press RUN and STOP RST simultaneously in running state to make the pump controller to stop 1 LOCAL...

Page 16: ...isabled 0 P00 18 Function restore parameter 0 No operation 1 Restore the default value 2 Clear fault records Note The function code will restore to 0 after finishing the operation of the selected func...

Page 17: ...cy given channel set by P00 06 or the voltage given channel set by P04 27 to change the feature of the curve Note Vb in the below picture is the motor rated voltage and fb is the motor rated frequency...

Page 18: ...V F frequency point 2 00 00Hz P04 06 V F voltage point 2 00 0 P04 07 V F frequency point 3 00 00Hz P04 08 V F voltage point 3 00 0 P04 09 V F slip compensation gain This function code is used to compe...

Page 19: ...e 25 PID control pause 26 Traverse Pause stop at the current frequency 27 Traverse reset return to the center frequency 28 Counter reset 29 Torque control prohibition 30 ACC DEC prohibition 31 Counter...

Page 20: ...o power frequency threshold or S input based Note Function 30 is relay output combining the functions 29 and 28 When one of the two conditions is met the relay output frequency is high 30 P06 04 Relay...

Page 21: ...t tE 21 EEPROM operation fault EEP 22 PID feedback disconnection fault PIDE 23 Brake unit fault bCE 24 Running time arrival END 25 Electrical overload OL3 26 31 Reserved 32 Short to ground fault 1 ETH...

Page 22: ...VMPP voltage reference 0 Voltage reference 1 Max powertracking 0 Apply voltage reference mode The reference is a fixed value and given by P15 02 1 Apply the reference voltage of Max power tracking The...

Page 23: ...t is the reference of water level control analog signal For details see P15 12 and P12 13 0 P15 12 Water level threshold 0 0 100 0 This code is valid when P15 11 water level control is based on analog...

Page 24: ...ported Otherwise it will be operated normally If the state is not continuous the delay counting will be cleared automatically 15 00 P15 21 Underload reset delay 0 0 1000 0s This parameter is used to s...

Page 25: ...ly after the time set by P15 26 The medium value is the current bus voltage and the limit is P15 30 Maximum Minimum reference voltage Current bus voltge P15 30 and it will update to P15 26 and P15 27...

Page 26: ...e main winding when applying the capacitance removed mode to control the 1PH motor 0 00 100 00A 0 00A P17 39 Current of the secondary winding Current of the secondary winding when applying the capacit...

Page 27: ...flow of thepump is reset and P18 13 and P18 14 are reset to zero to re calculate the flow After the reset P18 15 is automatically modified to 0 0 P19 Group Voltage Boost P19 06 Bus voltage reference...

Page 28: ...the setting of related function codes OC2 Overcurrent when deceleration OC3 Overcurrent when constant speed running UV Bus undervoltage 1 The voltage of the power supply is too low 2 The overvoltage s...

Page 29: ...ne 2 Check the PID feedback source END Running time reached The actual running time of the pump controller is longer than the preset running time Contact grundfos to adjust the preset running time OL3...

Page 30: ...If the water full alarm function is not enabled check whether there are terminal connections A tL Water empty alarm The water pumping tank is empty If the water empty alarm function is enabled the de...

Page 31: ...2 Normal temperature 3 No abnormal noise Input and output parameters 1 Input voltage 2 Output current 1 Input voltage within limit 2 Output current under the rated value 1 Every 1000 running hours 2...

Page 32: ...32 English GB...

Page 33: ...Chaitra Complex Jayanagar 7th block West Bangalore 560 070 Telefax 080 26711101 Service Email serviceindia grundfos com HYDERABAD GRUNDFOS Pumps India Private Limited Shop No 8 9 2nd Floor Lumbini Jew...

Page 34: ...grunfdos com The name Grundfos The Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos...

Reviews: