![Grundfos DMH 25X Installation And Operating Instructions Manual Download Page 38](http://html.mh-extra.com/html/grundfos/dmh-25x/dmh-25x_installation-and-operating-instructions-manual_2272014038.webp)
10.6.6 Checking the oil level
1. Switch off the pump, check the oil level and add oil, if necessary.
2. Refit the oil-filling screw (F).
Caution
After initial start-up and after each time the diaphragm is
changed, tighten the dosing head screws.
After approximately 6-10 operating hours or two days,
cross-tighten the dosing head screws using a torque
wrench.
Torques
Pump model
Torque
[Nm]
DMH 251, 10 bar
8-10
DMH 251, 16 bar
10-12
DMH 251, 25 bar
13-15
DMH 252
8-10
DMH 253
10-12
DMH 254
50-54
DMH 255
50-54
DMH 257
50-54
10.7 Replacing the diaphragm for dosing head with
double diaphragm
Warning
Wear protective clothing (gloves and goggles) when work-
ing on the dosing head, connections or lines!
The dosing diaphragm should be replaced with each gear
oil change.
Before removing the dosing head, valves and lines, empty
any remaining medium in the dosing head into a drip tray
by carefully unscrewing the suction valve.
Note
Only use original Grundfos gear oil!
For product numbers, see "Service kit catalogue" on
www.grundfos.com
10.7.1 Removing the dosing head
1. Close the suction and discharge lines and loosen the suction
and discharge valve connections.
2. Loosen the six dosing head screws (1q with 2q).
3. Remove the dosing head (2).
10.7.2 Replacing a double diaphragm
1. Clean the intermediate disk (3q), sealing rings (4q) and covering
rings (5q). After a diaphragm breakage, replace the parts by
new ones.
2. Remove both clamping sleeves (6q) slightly using pliers. After a
diaphragm breakage, replace the parts by new ones.
3. Measure the outer wall thickness of both new diaphragms (Q1
and Q2): s1
(Q1)
< s2
(Q2)
.
1q
2
2q
3q - 5q Q2
Q1
1)
s
1
< s
2
TM036474
Installation of diaphragm
1) The shape of the diaphragm varies depending on pump type.
Pos.
Components
1q
Dosing head screw
2q
Intermediate disk
2
Dosing head
Q1/Q2
See fig. Diaphragm on dosing-head side
3q - 5q
Caution
Observe correct installation of diaphragms (Q1 and
Q2)! See fig. Diaphragm on dosing-head side.
Fit the thinner diaphragm (Q1) on the dosing side and
the thicker diaphragm (Q2) on the oil side/pump side!
4. Fit both new diaphragms (Q1 and Q2) and the parts (3q - 5q) in
the correct order, as is shown in the diagrams (the clamping
sleeves (6q) are used for centring purposes).
2
5q
4q
3q
4q
5q
Q2
Q1
6q
3q
S
TM036475
Diaphragm on dosing-head side
Pos.
Components
S
Contact pressure gauge (installation position)
Q1
Diaphragm on dosing-head side
Q2
Diaphragm on oil side/pump side
3q
Intermediate disk
4q
Sealing rings
5q
Covering rings
6q
Clamping sleeves
38
English (GB)
Summary of Contents for DMH 25X