9.12 Timer menu / timer mode
In timer mode, a defined batch quantity is dosed with a defined
dosing flow. The first dosing starts after the start time t
1
has
elapsed. Batch dosing is then repeated after the repetition time t
2
has elapsed until the user stops the process by pressing the
"Start/Stop" button or with remote off.
• Input range for the batch quantity:
0.0 - 999.9 ml / 1.00 - 99.99 l / 100.0 - 999.9 l
• Input range for the times t
1
and t
2
:
1 min. < t
1
< 999 h / 1 min. < t
2
< 999 h
Input: hh:mm.
Fig. 52
Timer mode
Timer mode is controlled at the first and second function levels.
• The batch quantity and times t
1
and t
2
are set in the second
function level.
• Timer mode is enabled in the first function level.
Fig. 53
Setting timer mode
"OFF t" appears in the display.
1. Press the "Up" button.
– "ON t" appears in the display.
2. Press the "Start/Stop" button.
3. Use the "Up" and "Down" buttons to enter the desired dosing
flow.
– The selected dosing flow appears in the display.
4. Press the "Start/Stop" button.
5. Use the "Up" and "Down" buttons to enter the desired batch
quantity.
– The selected batch quantity appears in the display.
6. Press the "Start/Stop" button.
– "t1" appears in the display.
7. Use the "Up" and "Down" buttons to enter start time t
1
.
8. Press the "Start/Stop" button.
– "t2" appears in the display.
9. Use the "Up" and "Down" buttons to enter repetition time t
2
.
• Press the "Menu/Info" button (confirm the setting and move on
to the next menu item), or
• press the "Start/Stop" button (confirm the setting, close the
second function level and enable timer mode in the first
function level).
TM
03
66
16
45
06
Batch 1
Batch 2
Batch n
Dosing
Dosing
Dosing
Start time t
1
Repetition time t
2
Repetition time t
2
Caution
Risk of dosing errors!
If repetition time t
2
is not long enough to dose the
batch quantity at the set dosing flow within this time,
the pump continues dosing until the current batch
quantity is finished. The pump is then stopped and
the next batch dosing is triggered after the next
repetition time.
Batch dosing in timer mode may be insufficiently or
excessively triggered in the event of an error if the
pump/system is not monitored. The system must be
protected redundantly.
T
M
03
66
17
45
06
t
t
OFF
On
OFF
t
Up
Down
Stop
Start
Down
Up
Stop
Start
Stop
Start
Stop
Start
Down
Up
Stop
Start
Down
Up
Down
Up
6.00
t
l/h
890.0
t
ml
1:00
t
h
t 1
t
2:00
t
h
t 2
t
Menu
Info
Menu
Info
Menu
Info
Summary of Contents for DDI 150-4
Page 2: ...2 ...
Page 630: ...630 ...