English (GB)
11
1)
The maximum stroke frequency varies depending on calibration
2)
Data is based on measurements with water
3)
Maximum suction lift: 1 m, dosing capacity reduced (approx. 30 %)
4)
Length of suction line: 1.5 m, length of discharge line: 10 m (at max. viscosity)
5)
With E-Box
Electrical
data
Voltage
[V]
100-240 V, - 10 %/+ 10 %,
50/60 Hz
Length of mains cable
[m]
1.5
Max. inrush current for 2 ms (100 V)
[A]
8
Max. inrush current for 2 ms (230 V)
[A]
25
Max. power consumption P
1
[W]
24
5)
Enclosure class
IP65, Nema 4X
Electrical safety class
II
Pollution degree
2
Signal input
Max. load for level input
12 V, 5 mA
Max. load for pulse input
12 V, 5 mA
Max. load for
External stop
input
12 V, 5 mA
Min. pulse length
[ms]
5
Max. pulse frequency
[Hz]
100
Impedance at 0/4-20 mA analog input
[
Ω
]
15
Accuracy of analog input (full-scale value)
[%]
± 1.5
Min. resolution of analog input
[mA]
0.05
Max. resistance in level/pulse circuit
[
Ω
]
1000
Signal
output
Max. ohmic load on relay output
[A]
0.5
Max. voltage on relay/analog output
[V]
30 VDC/30 VAC
Impedance at 0/4-20 mA analog output
[
Ω
]
500
Accuracy of analog output (full-scale value)
[%]
± 1.5
Min. resolution of analog output
[mA]
0.02
Weight/size
Weight (PVC, PP, PVDF)
[kg]
2.4
2.4
2.6
Weight (stainless steel)
[kg]
3.2
3.2
4.0
Diaphragm diameter
[mm]
44
50
74
Sound
pressure
Max. sound pressure level
[dB(A)]
60
Approvals
CE, CB, CSA-US, NSF61, GOST/TR, C-Tick
Data
7.5-16
12-10
17-7
30-4