3.1.6 Foundation
WARNING
Falling objects
Death or serious personal injury
‐
Keep the product in a stable and fixed
position before installing it.
‐
Make sure that the foundation is suita-
ble for the weight of the product.
We recommend that you install the pump on a
concrete foundation which is heavy enough to provide
permanent and rigid support for the entire pump. The
foundation must be capable of absorbing any
vibration, normal strain or shock. The concrete
foundation must have an absolutely level and even
surface.
Place the pump on the foundation, and fasten it. The
base plate must be supported on the whole area.
The following instruction applies when mounting the
pump in both vertical and horizontal position. Place
the pump on the foundation, and fasten it. See fig.
Correct installation.
TM040342
Correct installation
f
h
Lf
Lf
W
f
TM068985
Foundation, vertical mounting
The recommended length and width of the foundation
are shown in fig. Foundation, vertical mounting. Note
that for pumps with motor size below or equal to 30
kW, the length and width of the foundation must be
200 mm larger than the base plate.
For pumps with motor size equal to 37 kW or above,
the length and width must always be 1.5 x 1.5 (Lf x
Wf) m.
L
h
W
f
L f
f
f
TM070574
Foundation, horizontal mounting
The foundation length and width must always be 200
mm larger than the length and width of the pump. See
fig. Foundation, horizontal mounting.
The mass of the foundation must be at least 1.5 times
the total mass of the pump. The minimum height of
the foundation (hf) can then be calculated:
hf =
Mpump × 1.5
Lf × Wf × δconcrete
The density (δ) of concrete is usually taken as 2200
kg/m
3
.
In installations where noiseless operation is
particularly important, we recommend that you use a
foundation with a mass up to 5 times that of the
pump.
The foundation must be provided with anchor bolts for
fixing the base plate. See fig. Bolt in foundation.
TM034589
Bolt in foundation
When the anchor bolts are in position, place the
pump on the foundation. Then align the base plate
using shims, if necessary, so that it is completely
horizontal. See fig. Alignment with shims.
14
English (GB)
Summary of Contents for CRN 125-11
Page 2: ......