6. Electrical installation
Fig. 7
Electrical connection
Carry out the electrical connection and protection according to
local regulations.
• The pump requires no external motor protection.
• Check that the supply voltage and frequency correspond to
the values stated on the nameplate. See section
.
• Connect the pump to the power supply with the plug supplied
with the pump as shown in fig. 7.
• Light in the control panel shows that the power supply has
been switched on.
TM
0
5
8
148
2
013
Click
1
0
1 x 230 V ± 10 %
∽ 50/60 Hz
3
4
5
Click
Click
6
1
17 mm
12 mm
7 mm
Ø 5.5 - 10 mm
Max. 1.5 mm
2
2
Warning
The pump must be connected to earth
.
The pump must be connected to an external
mains switch with a minimum contact gap of
3 mm in all poles.