Start-up
6.1
Preparations
NOTE:
Upon delivery, the drain outlet of the GENO-backwash filters MXA is open.
► Close the open drain outlet for 1.5 min:
1.
Press and hold the
button.
2.
Plug the mains plug into the socket.
3.
Release the
button.
NOTE:
Faulty connection/installation
● Filter is not closing, or the green lamp above terminal 20 only lights up dimly or
not at all.
► Disconnect the mains plug and check the installation of the product.