![Gruetzner LUBRICUS LUB-V User Manual Download Page 58](http://html1.mh-extra.com/html/gruetzner/lubricus-lub-v/lubricus-lub-v_user-manual_2270806058.webp)
56
6.4 Error and information messages on the display
The integrated microelectronic in the LUB-V permanently monitors the status. In case of abnor-
malities, an addressed message is issued and shown on the display. If the LUB-V has detected
an error and issues an error message for better identification of the error, no more lubricant is
pumped. In addition, the screen saver changes and gives an indication of the type of error by
displaying the error number. The errors must be eliminated after they occur. If you operate the
LUB-V in the operating modes Hour mode or Empty time mode, errors must be acknowledged on
the display. If the LUB-V is operated in pulse mode, the errors can only be acknowledged by the
PLC by sending a specific signal, see Chap. 8.2.
Symbol
Name
Explanation Remedy
Note E1
Cartrdige
empty
Place a new cartridge on the LUB-V
(see chapter 9.2)
No need to acknowledge the note; it is
automatically cleared after the shutdown
action.
Error E2
Overpressure;
the counter-
pressure at
the lubrica-
tion point is too
high
Check the lubrication point and elimi-
nate the cause.
Then trigger a Quick-Check for self-
testing of the LUB-V or disconnect the
power supply.
Error E3
Under- or over-
voltage
Switch off the LUB-V (OFF).
Check the power supply of the LUB-V.
Switch on LUB-V (ON).
Error E4
Decive error
Disassemble the LUB-V and return it
to the manufacturer together with the
lubricant cartridge and a description of
the fault.
A serious fault is usually in the electro-
nics of the LUB-V and cannot be repaired
by you on site.