6.3.4.3 Operating mode Pulse mode
No specific settings can be changed in the Settings menu within the operating mode Pulse mode,
since the LUB-V is integrated into a control system (PLC) and is commanded and controlled via
the PLC, see Chap. 8. Only the operating mode and the cartridge size can be set here, see Chap.
6.3.4.
Any other control signals can only be sent by the PLC.
In the pulse mode, the LUB-V must be integrated into a control system (PLC) and commanded
and controlled via this. In this case, a lubrication stroke/several lubrication strokes (one stroke
= 0.15 ml) is/are triggered at the LUB-V depending on signals from the external control (PLC).
Make sure that your PLC program is applicable to your application and that the lubrication point
is supplied with the correct amount of lubricant per time unit.
If this is the case, you can operate the LUB-V in pulse mode.
If this is
not
the case, modify your PLC program accordingly.
To use the LUB-V, it must first be properly mounted and installed and then switched on. Moun-
ting is very simple and described in detail in Chap. 5; switching on is described in Chap. 6.3.1.
DANGER
Machine elements that are not lubricated can cause failures resulting in
serious injury or death.
(
After sending a control signal, the response signal of the LUB-V must
be waited for, evaluated and interpreted in order to prevent an uncon-
trolled failure of the LUB-V.
Default settings Pulse mode: