Introducing Janus C4

janus

C4

Janus C4, is a network-enabled 

platform that allows you to manage 

your buildings security systems from 

one system; quickly, easily and in a 

timely manner.

2 Door Blade

You can snap the Door Blade into place on 

either type of controller to manage doors. 

Each door Blade enables the connection of 

two doors and two readers – plus a range 

of door elements such as locks and exit 

buttons. 

See page 12 

Single-Blade Controller

The compact Single-Blade 

controller is ideal when you only 

have a small space available. 

The device supports either one 

Door Blade, one I/O Blade or 

one OSDP Blade, and it can be 

powered via PoE or a separate 

external power supply. 

See page 6

Janus C4 

Server

The hardware is based on a modular architecture: two variants of 

intelligent controller can be combined with snap-in Blades for either 

door control or peripheral support.

Line Header

The line header is used for when you wish to 

use RS-485 communication to controllers.

The line header is connected to the IP 

network and allows communication for up 

to 6 controllers on an RS-485 line, note that 

no blades are supported by the line header. 

See page 10

Summary of Contents for Janus C4 Series

Page 1: ...Email info grosvenortechnology com Telephone 44 0 1279 838000 Web www grosvenortechnology com MISC LOCKS LIFT INTERCOM INTRUDER FIRE CCTV Getting Started Guide janusC4...

Page 2: ...controller is ideal when you only have a small space available The device supports either one Door Blade one I O Blade or one OSDP Blade and it can be powered via PoE or a separate external power supp...

Page 3: ...herals It enables the connection of up to 8 volt free relay outputs and 8 supervised inputs The Blade can be used in either Single Blade or Multi Blade controllers See page 16 Janus C4 Configurator Ap...

Page 4: ...RS 485 Line Header 6 controllers maximum supported by an RS 485 Line Header RS485 RS485 ONLY NETWORK HYBRID IP AND RS485 NETWORK RS 485 Line Header 6 controllers maximum supported by an RS 485 Line H...

Page 5: ...ected I O devices Readers locks and other connected I O devices Single Blade Controller with Lithium Polymer Battery PoE switch injector Mains Power Mains Power Battery PSU Multi Blade Controller with...

Page 6: ...red Disable PoE on the switch if not required In addition an optional 4 2V lithium polymer battery can provide backup for all connected equipment during power outages When selecting the most suitable...

Page 7: ...to follow this step Connect the IP and or RS485 cable as required please note for all controller configuration IP must be connected first If using PoE IP connection will apply power to the controller...

Page 8: ...ition an optional 12V sealed lead acid battery can provide backup for all connected equipment during power outages note that all data is retained when power is lost even without a battery fitted When...

Page 9: ...ions see page 12 For I O Blade connections see page 16 For OSDP Blade connections see page 14 Run cabling to the enclosure from all the doors readers locks inputs and outputs that are to be connected...

Page 10: ...powering up for example if PoE and external mains the PoE will be seen first and the external mains ignored Disable PoE on the switch if not required In addition an optional 4 2V lithium polymer batt...

Page 11: ...se is closed 1 1 Install the lithium polymer back up battery if required The battery ensures operation of equipment during power outage Note that data is retained even without a battery fitted 2 2 Con...

Page 12: ...S485 A RS485 B Clock D1 Data D0 Valid Beeper Tamper 12 V 5 V GND RS485 A RS485 B Clock D1 Data D0 Valid Beeper Tamper HID Reader connections Advance Reader connections ADVANCE 2 Door Blade Door Reader...

Page 13: ...se the lock The door would remain locked in the case of a power failure A Fail Safe lock requires power to lock the door The door would be unlocked in the case of a power failure External Lock Power S...

Page 14: ...V GND RS485 A RS485 B OSDP Reader connections _ Exit switch Door sensor 12 V Sounder GND REX GND Sensor Contact Only no fault detection Reader Connections Door Connections The Door Sensor circuit may...

Page 15: ...o lock the door The door would be unlocked in the case of a power failure By default locks use the internal power supply If required the door Blade external power supply can be used External Lock Powe...

Page 16: ...ler or the Multi Blade controller to support extra peripherals Input switch 1K 1K GND In 1 Out NO Com Out NC 1 Normally Closed Contact Common Normally Open External power Supervised may optionally be...

Page 17: ...4 0 6 When accessing Janus C4 the application username is support and the password is Support123 Note This only applies if you are using the Janus C4 mini PC If you install the Janus C4 application ma...

Page 18: ...he Janus C4 Mini PC 1 On the Janus C4 mini PC navigate to the Control Panel Network and Internet Network Connections and alter the IPv4 address of the mini PC ensuring IP Subnet and Gateway is all rel...

Page 19: ...he services app and restart the service Janus C4 Application Server note that restarting the mini PC is also acceptable 4 Once completed log into Janus C4 and the Advance configurator and bring online...

Page 20: ...are the Janus C4 system Note Full details of the installation process can be found in the Janus C4 Technical Guide 1 Install Janus C4 Server ServerSetup exe The default account is user name support pa...

Page 21: ...dress format is http xxx xxx xxx xxx c4client where xxx xxx xxx xxx is the IP address of the Janus C4 server 3 Click on the Install button This will download the Janus C4 client installer and install...

Page 22: ...Licenses to open the panel with the current license information If you own a trial version of the Janus C4 system and you do not have a license the attributes in this panel are empty 2 Click the Activ...

Page 23: ...rmed in the Configurator The installation of the Configurator program will add a shortcut to the utility on the desktop of the Janus C4 server Double click on the desktop icon to access the Configurat...

Page 24: ...nstall This is used to add the controllers and line headers to the system it is also used to configure RS 485 only controllers all controllers must be initially configured via IP Replace This is used...

Page 25: ...xxx xxx xxx 8080 janusc4 where xxx xxx xxx xxx is the IP address of the Janus C4 server 4 Under the application role select either IP Controller or 485 Controller note that to configure an RS 485 con...

Page 26: ...to 10 mins please do not remove the controller from the network until the controller LED is for a Line Header flashing Green connected on the network and for an RS 485 controller flashing steady Ambe...

Page 27: ...or DePoll if the reader is OSDP Isolate This is for OSDP readers only and declines all card reads whilst monitoring if the OSDP reader is online Address The address of the reader on the controller Th...

Page 28: ...ders inputs outputs doors etc and is always 1 for OSDP readers So a door in position 2 on a door blade in controller slot 4 would be addressed as 402 Sensor Type Select if you have a door contact also...

Page 29: ...variety of security devices from camera systems to intrusion detection into one view Drivers for many security devices can be installed in Janus C4 Operators of the Janus C4 system can be assigned ro...

Page 30: ...lation guides documents on integrations as well as a range of quick guides to help you get the most from Janus C4 Once the controllers doors and readers are configured the set up of the system can be...

Page 31: ...nor Technology Ltd Endeavour House Coopers End Road Stansted Essex CM24 1SJ United Kingdom Tel 44 0 1279 838000 Email ac support grosvenortechnology com Web www grosvenortechnology com JC4 GSG v1 3 Ma...

Reviews: