13

Care

Trouble Shooting

We want to ensure that you get long-lasting 
satisfaction and pleasure from your GROHE 
fitting. Therefore, please read the following 
care instructions because damage to the 
surface and underlying material resulting 
from improper treatment is not covered by 
our guarantee.

Do not use any abrasive sponges or scou-
ring agents for cleaning. We also advise not 
to use cleaning agents containing solvent or 
acid, limescale removers, household vinegar 
and cleaning agents with acetic acid. They 
are aggressive to the surface and will leave

your fitting dull and scratched. As the for-
mulations of commercially available cleaning 
agents frequently change, we cannot gua-
rantee they will provide the gentle care our 
fitting deserves.

Clean the fitting with a little soap and a moist 
cloth only, then simply rinse off and wipe dry. 
You can avoid lime spots by drying the fitting 
each time it is used. If lime deposits do oc-
cur, remove them with 

Grohclean 

(ref.

no. 45 939), our environment-friendly 
cleaning liquid. 

Grohclean

 is specially 

formulated to  gently clean the surface of our 

Problem

Cause

Remedy

Thermostatic valve 
opens through hot

Hot and cold water supplies have 
been connected in reverse

Rotate the thermostatic mixing 
valve 

Range of temperature 
adjustment restricted

High pressure difference between 
hot and cold water supply

Install flow limiter see chapter 

Exposed Installation

Shower insufficiently 
cold or hot

Adjustment incorrectly set

Hot water supply temperature too 
low

Refer to the instructions in chapter 

Adjustment

Check hot water source tempera-
ture setting

No flow of hot or cold 
water

Either the hot or cold side is not 
fully pressurized

Debris caught inside the inlet of 
the control unit

Replace non-return valve, refer to 
chapter 

Maintenance

Remove mixing valve and flush out 
or remove any debris lodged in-
side the hot or cold inlets or filters

Hot water emerges to 
cold water supply or 
vice versa

Non return valves are damaged in 
cause of lime

Replace non-return valve, refer to 
chapter 

Maintenance

Summary of Contents for Avensys 34 084

Page 1: ...1 I 5 N 9 GR 13 TR 17 BG 21 RO 25 GB 2 NL 6 FIN 10 CZ 14 SK 18 EST 22 CN 26 F 3 S 7 PL 11 H 15 SLO 19 LV 23 RUS 27 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 Avensys Avensys 95 620 431 M 205474 11 06 34 084 GB...

Page 2: ...I Valve Body Wallplugs Screws Escutcheons Filters Threaded Rings Flow Limiters Handshower Filter Flexible Hose Shower Rail Outlet Nipple Plug Backplate Table Of Contents Installation Dimensions mm 1 2...

Page 3: ...II Spare Parts 3 4...

Page 4: ...seal 01 287 10 9 4 Filter 06 768 5 9 5 Escutcheon 00 197 2 10 Handshower 28 261 1 11 Filter 07 002 2 12 Shower rail 28 666 1 12 1 Sliding shower holder 07 659 1 12 2 Shower rail holder 45 362 1 12 2 1...

Page 5: ...oughly flushed before installing the mixing valve GROHE recommends installing isolating valves upstream of the mixing valve for servicing purposes New Water Regulations This GROHE product should be in...

Page 6: ...re preassembled to the valve body The valve body is fixed to the backplate by a set screw In case of exposed installation with supply pipes from above or below rotate inlet elbows 90 and connect to 15...

Page 7: ...he escutcheons H over the supply pipes and install filters J see Fig 7 10 Slide the valve body E with elbows and compression nuts loosely over the supply pipes The body must touch the backplate If not...

Page 8: ...must be dismounted rotated 180 and reinstalled Shower Hose Connection 1 Close free outlet with plug K see Fig 10 2 Remove O ring seal L1 3 Turn outlet nipple L 180 and fit O ring seal L1 4 Thread the...

Page 9: ...ounter clockwise to fully open position and open water flow 2 Turn the temperature handle counter clockwise to maximum hot water temperature 3 Lever out cap M see fig 11 4 Unscrew screw N 5 Pull off t...

Page 10: ...nections and take valve from the supplies 13 Screw out control unit U see Fig 14 14 Take out O ring seal U1 15 Take out wax element V slider W and spring X Inspect and clean all parts replace if neces...

Page 11: ...lip P1 16 Reinstall the temperature handle O in position hot water 17 Fix temperature handle with screw N and cover with cap M Readjustment is necessary after every maintenance operation on the contro...

Page 12: ...posits do oc cur remove them with Grohclean ref no 45 939 our environment friendly cleaning liquid Grohclean is specially formulated to gently clean the surface of our Problem Cause Remedy Thermostati...

Page 13: ...14...

Page 14: ...t all functional defects for which we are responsible limitations see E F B It is our option if we correct the defects by repair or replacement C During the above guarantee period we will not charge f...

Reviews: