Malfunction finding procedures
A number of procedures to determine the correct cause of a certain malfunction are described
below.
Procedure to check pressure switch (valve) and its cable
1.
Disconnect the 2-pole connector from the pressure switch.
2.
Measure the resistance between the two contacts using a digital multimeter. When the sys-
tem is pressureless , the resistance should be 22K ohm. If required, remove the switch to make
sure that no pressure below the pressure switch is present. Remove only the upper part, the
diverter valve can be left in place.
3.
If possible, mount a pressure gauge that is suitable for a grease pressure up to 250 bar
between the diverter valve and the pressure switch and bleed this connection before use.
4.
Switch ignition ON.
5.
Start a cycle test by pushing the test push-button at the pump.
6.
Check the switching moment of the pressure switch using the digital multi-meter. When the
adjusted pressure (see the side of the pressure switch) is reached the contact should be closed,
the resistance should ± 0 ohm.
7.
Switch ignition OFF for ending the cycle test.
If the pressure switch functions properly, the cable should be checked for internal damage.
8.
Connect both contacts of the connector of the pressure switch with a separate wire.
9.
Disconnect the pump connector.
10. Measure the resistance between pin 7 and 8 of the pump connector. The measured resistance
should be ± 0 ohm.
11. Remove the wire between the contacts of the connector of the pressure switch. The digital
multimeter should read an
open load
.
ATTENTION
If a pressure switch without a resistor is being used in the greasing system you should measure an
open load.