Automatic Greasing System
Twin-3
EG1703P03
4.6.3
Malfunction finding table
To make it easier to find malfunctions (when no Uni- or PC-GINA is available), refer to the
malfunction finding table. In this table, probable causes of malfunctions and their solutions are
listed. Because malfunction reports through the Twin display varies a little from the reports
through the signal lamp, a separate table is inserted.
Malfunction reports of signal lamp
Malfunction
Cause
Solution
1. Lamp does not flash when the
ignition has been switched
ON.
a. No supply voltage on pin 1.
a. Check fuse and replace if
necessary.
b. No ground wire connection
with control unit or signal
lamp (pin 2).
b. Check and repair earth
ground wire connection if
necessary.
c. Signal lamp broken.
c. Replace signal lamp if
necessary.
d. Wiring interruption between
power supply and the control
unit or between control unit
and signal lamp.
d. Check and repair wires if
necessary.
2. Lamp flashes for 2 minutes
(0,5-sec. on/ 0,5-sec. off) at
the beginning of each cycle.
Minimum level in the reservoir
has been reached.
Resets itself by refilling the
reservoir.
3. Lamp continuously lit after
the ignition has been
switched ON.
a. The last 10 greasing cycles
failed. The control unit
switched OFF the pump due
to a number of failed cycles in
succession in order to prevent
possible environmental
pollution in case of damaged
hoses.
a. Push the test push-button at
the pump for 1 second to
reset the report. Locate the
cause of the malfunction and
repair it (see point 4).
b. Minimum level report in
combination with no pressure
in the system within the
maximum pumping time.
b. Refill the reservoir to reset
the malfunction report.
Perform a system test and
bleed the system if necessary.