background image

This manual provides information for:

OPERATOR MANUAL

IMPORTANT INFORMATION, KEEP FOR OPERATOR

PART NUMBER 141601 REV F (07/14)

MODEL HY-6G 

HYPERSTEAM™ 

ATMOSPHERIC 

CONVECTION STEAMER

· Self Contained

· Gas

· Capacity: 6 Steamer Pans (12” x 20” x 2-1/2”)

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.  

READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND 

WARNINGS CONTAINED IN THIS MANUAL.

WARNING / FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

POST IN A PROMINENT LOCATION

Instructions to be followed in the event user smells 

gas.  This information shall be obtained by consulting 

your local gas supplier.  As a minimum, turn off the gas 

and call your gas company and your authorized service 

agent.  Evacuate all personnel from the area.

WARNING

Improper  installation,  adjustment,  alteration,  service 

or  maintenance  can  cause  property  damage,  injury  or 

death.  Read the installation, operating and maintenance 

instructions thoroughly before installing or servicing this 

equipment.

NOTIFY CARRIER OF DAMAGE AT ONCE

It is the responsibility of the consignee to inspect the container upon receipt of 

same and to determine the possibility of any damage, including concealed dam-

age. Unified Brands suggests that if you are suspicious of damage to make a 

notation on the delivery receipt. It will be the responsibility of the consignee to file 

a claim with the carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

Information contained in this document is known to be current and accurate at the time 

of printing/creation.  Unified Brands recommends referencing our product line websites, 

unifiedbrands.net, for the most updated product information and specifications.

1055 Mendell Davis Drive 

Jackson, MS 39272

888-994-7636,  fax 888-864-7636

unifiedbrands.net

Summary of Contents for HYPERSTEAM HY6G

Page 1: ...tallation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing...

Page 2: ...O NOT USE PLASTIC PIPE DRAIN MUST BE RATED FOR BOILING WATER WARNING DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN WARNING BLOCKING THE STEAM GENERATOR OR CAVITY DRAIN SCREEN MAY BE HAZARDOUS...

Page 3: ...ONTENT OF ANY PRODUCT IS UNCLEAR CONSULT THE MANUFACTURER NOTICE USE NO DE GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM HYDROXIDE OR THAT IS ALKALINE WARNING USE OF ANY REPLACEMENT PARTS OTHER...

Page 4: ...NG CO 1310 T Seaboard Industrial Blvd Atlanta Georgia 30318 NATIONAL FIRE PROTECTION ASSOCIATION 60 Batterymarch Park Quincy Massachusetts 02269 NFPA 70 The National Electrical Code NFPA 54 Installati...

Page 5: ...on older models has been replaced by touch pad controls and the distinctive symbol for steam is integrated into the panel design The new model also has fewer panel louvers on the right side The drain...

Page 6: ...s than 30 ppm Silica less than 12 ppm Undissolved Solids less than 5 microns 1 Do not rely on unproven water treatments which are sold for scale prevention or scale removal They don t always work The...

Page 7: ...m the skid Be careful to avoid personal injury Strap edges may be very sharp particularly where cut Write down the model number serial number and installation date Space for these entries is provided...

Page 8: ...I NFPA 70 1987 or latest edition AN ELECTRICAL GROUND IS REQUIRED The electrical schematic is located in the service compartment and in this manual Maximum load is 2 AMPs In Canada provide electrical...

Page 9: ...ater used for steam suppression in the drain is much greater than the amount of water used to generate steam The second connection on steamers see illustration under Water Quality Treatment section pe...

Page 10: ...ss the ON switch for the desired steamer cavity The steam generator will fill with water NOTE The door MUST be closed for the main burner to work 8 When the steam generator has filled with water the b...

Page 11: ...ndicator light comes on when the steam generator is too hot The unit will automatically shut off and cannot be turned on again until the steam generator cools and the HI TEMP indicator light goes out...

Page 12: ...d The timer will automatically run the steamer for the set time and then turn it off A red light will come on and a beeper will sound Steam production stops If you want to steam continuously turn the...

Page 13: ...ic wool or a brush with soft bristles g Spray bottle h Measuring cup i Nylon pad j Towels k Plastic disposable gloves l Funnel B Procedure 1 Outside a Prepare a warm solution of the mild detergent as...

Page 14: ...30 minutes When delime cycle is com plete DELIME light will appear DONE light will flash and beeper will beep STEP 7 Press ON OFF to turn steamer off Let cavity cool for 5 minutes or longer Open door...

Page 15: ...eaking from around the door take the following steps 1 Check the door gasket Replace if it is cracked or split 2 Inspect the cooking chamber drain to be sure it is not blocked 3 Adjust the latch pin t...

Page 16: ...t Authorized Service Rep Only g Is spark ignition cable connected to module X Steam generator does not fill with water User a Is the ON switch depressed b Is the water supply connected c Is the water...

Page 17: ...Door Handle 129723 6 Door Gasket 124849 7 Left Pan Rack 094148 8 Blower Cover Rack 096788 9 Door Locking Pin 078914 9a Door Pin Lock Nut 003823 10 Timer 096826 11 Timer Knob 123100 12 Mylar Overlay Pl...

Page 18: ...Thermostat 088865 5 Steam Port 141366 6 Steam Hose Top 141461 7 Steam Hose Bottom 141462 8 1d Hose Clamp 127525 9 Fan Motor 096740 10 Motor Capacitor 096812 11 Control Board 141082 12 Light Timer PC B...

Page 19: ...nifold 141499 2 Outer Gas Manifold 141348 3 Igniter Cable 096728 4 1 2 Outer High Heat Tube 141338 5 1 2 Inner High Heat Tube 141339 6 Outer Flue 096854 7 Inner Flue 096854 x Steam Generator Drain Val...

Page 20: ...096868 3 Motor Insulator 094135 4 Fan 096790 5 Timer 096826 6 Control Board 141082 7 Timer Knob 123100 8 Door Switch 096857 9 Steam Port Kit 141617 10 Ready Thermostat 088865 11 Steam Port Gasket 0992...

Page 21: ...e Left 141285 141424 7 2 1 4 Hose Clamp 073259 8 1d Hose Clamp 010873 x 1 4 Hose Clamp 095656 10 d Elbow with Fitting 057217 x Top Cavity Drain Hose 141490 x Bottom Cavity Drain Hose 141491 13 3 Botto...

Page 22: ...085153 4 Solenoid Gas Valve 099906 5 Pilot Gas Switch 087951 6 Water Inlet Mounting for 2 Outlet Split Water 071235 7 Control Transformer 094164 8 Steam Generator Drain Valve 074594 9 High Heat Flame...

Page 23: ...OM HY 6G 23 Electrical Schematic...

Page 24: ...24 OM HY 6G Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 25: ...OM HY 6G 25...

Page 26: ...26 OM HY 6G...

Page 27: ...OM HY 6G 27...

Page 28: ...REV F 07 14 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2014 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...