background image

This manual provides information for:

OPERATOR MANUAL

IMPORTANT INFORMATION, KEEP FOR OPERATOR

PART NUMBER 121001 REV D (10/10)

MODEL HY-6CAV 

DOMESTIC

 

HYPLUS™ 
ATMOSPHERIC 
STEAMER CAVITIES

· For Models: HY-6SM, HY-6SG, HY 6SE
· Capacity: 6 Steamer Pans (12” x 20” x 2-1/2”)

THIS  MANUAL  MUST  BE  RETAINED  FOR  FUTURE  REFERENCE.  
READ,  UNDERSTAND  AND  FOLLOW  THE  INSTRUCTIONS  AND 
WARNINGS CONTAINED IN THIS MANUAL.

WARNING / FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

WARNING

Improper  installation,  adjustment,  alteration,  service 

or  maintenance  can  cause  property  damage,  injury  or 

death.  Read the installation, operating and maintenance 

instructions thoroughly before installing or servicing this 

equipment.

It is the responsibility of the consignee to inspect the container upon receipt of 
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a 
notation on the delivery receipt. It will be the responsibility of the consignee to file 
a claim with the carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

Information contained in this document is known to be current and accurate at the time 

of  printing/creation.    Unified  Brands  recommends  referencing  our  product  line  websites, 

unifiedbrands.net, for the most updated product information and specifications.

1055 Mendell Davis Drive 

Jackson, MS 39272

888-994-7636,  fax 888-864-7636

unifiedbrands.net

E

T

S

AM

WATER FILL

LOW WATER

HIGH PRESSURE

READY

ON

Summary of Contents for HY-6CAV

Page 1: ...instructions thoroughly before installing or servicing this equipment It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any da...

Page 2: ...E STEAMER DISCONNECT ELECTRIC POWER KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT SERIOUS INJURY COULD RESULT WARNING LET C...

Page 3: ...AUTHORIZED SERVICE AGENTS VOIDS ALL WARRANTIES AND CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT SERVICE PERFORMED BY OTHER THAN FACTORY AUTHORIZED PERSONNEL WILL VOID ALL WARRANTI...

Page 4: ...Schematics page 21 23 Service Log page 24 UNDERWRITERS LABORATORIES INC 333 Pfingsten Road Northbrook Illinois 60062 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Minnesota 55102 800 328 3663 o...

Page 5: ...ilers gas fired or electrically heated respectively built into their cabinet bases Model HY 6SM has no steam generator and requires a clean steam supply suitable for food contact The drain system incl...

Page 6: ...trical schematic is located in the electrical enclosure and in this manual In Canada provide electrical service in accordance with the Canadian Electrical Code CSA C22 1 Part 1 and or local codes 2 Wa...

Page 7: ...e Do NOT use plastic pipe the piping must be able to withstand steam and hot water Extend the drain piping to a nearby floor drain Piping of 1 1 4 NPT or 1 1 2 NPT is acceptable for distances of six f...

Page 8: ...old water treated 4 Cold water untreated 5 Not used 6 Drain for boiler steamers and condenser spray Also for kettle condensate and sink where used 7 Electrical conduit through underside terminals at t...

Page 9: ...lable for the cavity choose one of the following a Set the timer to the desired time for timed steaming b Turn the timer to the manual ON position for continuous steam NOTE The door must be shut befor...

Page 10: ...d food into pans so that it is in uniform layers For best results pans should be filled to about the same levels and should be even on top 5 Open the door and slide the pans onto the supports If you w...

Page 11: ...e parts thoroughly with clean water and replace fan baffle partition Make sure the drain holes at the back of each cavity are free of food particles or other debris WARNING DISCONNECT THE POWER SUPPLY...

Page 12: ...oor Latch Adjustment If steam or condensate is observed leaking from around the door take the following steps 1 Check the condition of the door gasket Replace it if it is cracked or split 2 Inspect th...

Page 13: ...Is the green light in the ON OFF switch lit d Are any fuses blown No steam to cavities a On HY 6SG and HY 6SE Has steam pressure developed b On HY 6SM Is steam supply turned on c Is the door closed D...

Page 14: ...14 OM HY 6CAV Parts List HY 6SG HY 6SE and HY 6SM Steamer Cavity Only...

Page 15: ...18 Nut 10 32 071256 19 Nut 8 32 002632 20 Transformer 75VA 480V SE 480V 121717 20 Transformer 75VA 208 240V SE 121716 Key Description Part No 20 Transformer 75VA 110V SG 121715 21 Bracket Transformer...

Page 16: ...16 OM HY 6CAV Parts List KEY DESCRIPTION PART NO 1 Motor 096739 2 Slinger Washer 096831 3 Motor Mounting Plate 094134 4 Shaft Seal 096868 5 Plate Seal Holder 096752 Motor Fan Assembly...

Page 17: ...Cover Right Side HY 6SG 143778 2 Cover Left Side 123184 3 Cover Assembly Top 123182 4 Screw 10 32 x 3 8 Truss Head 004173 Sheet Metal Doors KEY DESCRIPTION PART NO 5 Retainer Top 123156 6 Screw 8 32...

Page 18: ...y Incl Door Spring 078911 094144 6 Latch Spring 078911 7 Latch Pin 078914 X Left Pan Rack 094148 Key Description Part No 8 Lock Nut 003823 9 Inner Panel 094141 10 Door Spacer 071206 11 Door Screws 057...

Page 19: ...on Part No 1 Solenoid Valve Spray Condenser 099221 2 Hose d ID x 8 Long 099282b 3 Rubber Flap 099213 Key Description Part No 4 Spacer 099212 5 Hose Outlet 1 ID x 3 Long 099280b 6 Anchor Coupling d NPT...

Page 20: ...5 Bushing Strain Relief 121742 6 Screw Hex Slot Washer HD Cap 8 32 x 1 4 Long 074242 7 Screw Round HD 8 32 x 1 1 4 Long 005056 Key Description Part No 8 Weld Assembly Electronic Cabinet Bottom 137256...

Page 21: ...OM HY 6CAV 21 Electrical Schematic HY 6SM HyPlus Steamer Cavities...

Page 22: ...22 OM HY 6CAV Electrical Schematic HY 6SE HyPlus Steamer Cavities...

Page 23: ...OM HY 6CAV 23 Electrical Schematic HY 6SG HyPlus Steamer Cavities...

Page 24: ...24 OM HY 6CAV Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By Service Log...

Page 25: ...OM HY 6CAV 25...

Page 26: ...26 OM HY 6CAV...

Page 27: ...OM HY 6CAV 27...

Page 28: ...REV D 10 10 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2010 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Reviews: