Individual measurements
General:
- Switch on the meter by pressing the start
button; the meter will immediately carry out
a measurement
- Check the battery status in the event a
number of measurements are to be made
- The WCM-meter must be set up for the
correct type of stone wool
Activation of individual measurements:
- Press the start button to start a new individual
measurement
Switching the meter off:
- The meter will automatically switch itself off
once it has not been used for 1 minute
- In the menu screen, move to "fast off" and
confirm by pressing the menu button
Multi-measurements
General:
- Switch on the meter by pressing the start
button
- Check the battery status
- Check whether the slab type has been set
correctly
Activation of multi-measurements:
- In the menu screen move to "start multimeasu-
rements" using the
N
button, and confirm with
the menu button
- Enter the required number of measurements
for each block (a number between 1 and 250)
- Enter the number of measurements for each
block by pressing the
M
or
N
buttons, and con-
firm with the menu button
- The default is 25 measurements per block in
10 blocks
- Press "start" to begin the measurements
- When "measurements finished" is displayed
correct measurements can be saved by pressing
the
M
arrow (‘yes’); in the event of incorrect
measurements, press the
N
arrow (‘no’)
- Once all the measurements have been carried
out in a block, measurements will continue in
the next block
Quick Guide
WCM-control
Version 5.0
Reading out average values and the stan-
dard deviation of the measurement blocks:
- The average values of the WC, EC and T for
each measurement block, and their standard
deviations, can be read out during or after the
series of measurements
- This function is activated by moving to "statis-
tics" using the
N
arrow and confirming with the
menu button
Switching off multi-measurements:
- Switch off the multi-measurements by moving
to "multi-measurements off" using the
M
or
N
arrows.The memory will be deleted.
- In the "multi-measurements" mode the meter
will remain switched on for a period of 30
minutes after the last measurement; this allows
for notes to be taken of the measurements if so
required.
- The meter can be switched off manually from
the menu screen by moving to "fast off" using
the
N
arrow, and then confirming this with the
menu button and the
M
arrow (‘yes’).The
stored measurements will be saved.
Activating logging
measurement
General:
- Switch on the meter by pressing the start
button
- Check the battery status
- Check the time setting of the clock
Activation of logging measurement:
- In the menu screen move to "start logging",
and confirm with the menu button
- Enter the starting date and the starting time
using the
M
or
N
arrows, and confirm with the
menu button
Always set the starting time to at least
3 minutes after the current time on the
meter.
- Enter the interval (in minutes), and confirm
with the menu button
- Enter the number of days, and confirm with the
menu button. Please note that if the memory
capacity is exceeded (2300 measurements), the