-14-
Model G1014Z/G1014ZX (Mfd. Since 08/22)
4. Use wire nuts to connect wires as indicated
in
Figure 8. Twist wire nuts onto their respec-
tive wires and wrap them with electrical tape
so they will not come loose during operation.
5. Close and secure motor junction box.
6. Install 6-15 plug on power cord, according to
plug manufacturer's instructions.
— If plug manufacturer's instructions are not
available, NEMA standard 6-15 plug wir-
ing is provided beginning on
Page 52.
Figure 8. Motor rewired for 220V.
Start
Capacitor 200MFD 125VAC
Ground
Connect Wires
with Wire Nuts
Figure 7. Motor prewired for 110V.
The voltage conversion MUST be performed by
an electrician or qualified service personnel.
The voltage conversion procedure consists of
rewiring the motor and installing the correct plug.
A wiring diagram for each machine is provided for
your reference in the back of this manual, begin-
ning on
Page 52.
Items Needed
Qty
•
Phillips Head Screwdriver #2 ...................... 1
•
Electrical Tape ............................. As Needed
•
Wire Cutters/Stripper ................................... 1
•
NEMA 6-15 Plug .......................................... 1
Converting Voltage
to 220V
To convert the machine to 220V operation:
1. DISCONNECT MACHINE FROM POWER!
2. Cut off the existing 5-15 plug.
3. Open the motor junction box, then loosen two
wire nuts indicated in
Figure 7.
Ground
Start
Capacitor 200MFD 125VAC
Remove
These
Wire
Nuts