SECTION 4: DESIGNING A SYSTEM
General
Always guard against stat-
ic electrical build up by
grounding all dust collec-
tion lines.
The Model G0944/G0944HEP works quite well as
a point-of-use dust collector, or for collecting dust
from up to two machines simultaneously.
Tips for Optimum Performance
•
Avoid using more than 10' of flexible hose on
any ducting line. The ridges inside flexible
hose greatly increase static pressure loss,
which reduces suction performance.
•
Keep ducts between the dust collector and
machines as short as possible.
•
Keep ducting directional changes to a mini-
mum. The more curved fittings you use, the
greater the loss of suction at the dust-produc-
ing machine.
•
Gradual directional changes are more effi-
cient than sudden directional changes (i.e.
use 45° elbows in place of 90° elbows when-
ever possible).
•
The simpler the system, the more efficient
and less costly it will be.
Always make sure there are no open flames
or pilot lights in the same room as the dust
collector. There is a risk of explosion if too
much fine dust is dispersed into the air with
an open flame present.
Figure 13. G0944 performance curve table and
data.
Figure 14. G0944HEP performance curve table
and data.
The air flow test probe is located 1.5x duct diameter upstream
from the air inlet. Test pipe length is a minimum of 10x duct
diameter.
G0944 Performance Curve
1200
1000
800
600
400
200
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0 11.0
1250
CFM
STATIC PRESSURE (Inch/H2O)
1.5 HP DUST COLLECTOR PERFORMANCE RESULTS
Max CFM Max SP
HP
Volts
Inlet
Impeller
1250
10.4
1
1
⁄
2
HP
110V
6"
12
3
⁄
4
"
Restrictor Plate Dia. 6"
5"
4"
3"
2"
Static Pressure
(Inch/H2O)
3.5
4.7
7.4
9.6
9.9
CFM
1096 1001 782 475
224
The air flow test probe is located 1.5x duct diameter upstream
from the air inlet. Test pipe length is a minimum of 10x duct
diameter.
G0944HEP Performance Curve
1500
1250
1000
750
500
250
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0 11.0
1280
CFM
STATIC PRESSURE (Inch/H2O)
1.5 HP DUST COLLECTOR PERFORMANCE RESULTS
Max CFM Max SP
HP
Volts
Inlet
Impeller
1280
10.4
1
1
⁄
2
HP
110V
6"
12
3
⁄
4
"
Restrictor Plate Dia. 7"
6"
5"
4"
3"
2"
Static Pressure
(Inch/H2O)
1.2
1.8
3.1
5.6
8.7
10.2
CFM
972
675 409 214 95
34