18. Remove (3) jumpers from their terminals (see
Figure 22). One jumper will not be reused.
14. Disconnect the U5, V5, and W5 wires from
their terminals (see
Figure 19).
15. Connect wires U5, V5, and W5 as shown in
Figure 20.
W3
W5
W1
W2
TABLE ELEVATION
MOTOR (440V)
W3
W1
W2
TABLE ELEVATION
MOTOR (220V)
W5
(Motor Rewired for 440V)
To Electrical Box
U2
V2
V3
V5
V1
U1
U5
U3
U2
V2
V3
V5
V1
U1
U5
U3
Figure 20. Table elevation motor wired for 440V.
16. Close table elevation motor junction box.
17. Open feed motor junction box (see Figure 21
).
Figure 21. Feed motor junction box.
19. Rearrange jumpers as shown in Figure 23.
FEED MOTOR (220V)
W2
W2
W1
FEED MOTOR (440V)
W2
W2
W1
(Motor Rewired for 440V)
To Electrical Box
U2
V2
V1
U1
U2
V2
U2
V2
V1
U1
U2
V2
Figure 23. Feed motor wired for 440V.
20. Close feed motor junction box.
21. Close electrical box and lower left access door.
FEED MOTOR (220V)
W2
W2
W1
FEED MOTOR (440V)
W2
W2
W1
(Motor Rewired for 440V)
To Electrical Box
U2
V2
V1
U1
U2
V2
U2
V2
V1
U1
U2
V2
Figure 22. Feed motor wired for 220V.
Jumper
13. Remove (2) jumpers from their terminals (see
Figure 19). Jumpers will not be reused.
W3
W5
W1
W2
TABLE ELEVATION
MOTOR (440V)
W3
W1
W2
TABLE ELEVATION
MOTOR (220V)
W5
(Motor Rewired for 440V)
To Electrical Box
U2
V2
V3
V5
V1
U1
U5
U3
U2
V2
V3
V5
V1
U1
U5
U3
Figure 19. Table elevation motor wired for 220V.