Model G0857/G0858 (Mfd. Since 07/19)
-47-
8. Tighten outfeed table lock located so outfeed
table will not move during operation.
9. Re-install cutterhead guard, fence, and rear
access panel on stand.
10. Verify proper operation of cutterhead guard
(refer to
Checking/Adjusting Cutterhead
Guard on Page 53 for instructions).
G0858
G0857
G0857
Figure 54. Knife or insert at TDC.
Top Dead
Center
Bottom Dead
Center
Top Dead
Center
G0858
Figure 55. Using straightedge to check outfeed
table height.
Straightedge
Outfeed
Infeed
Straightedge
Outfeed
Infeed
6. Use motor pulley to rotate cutterhead until
one knife or insert is at TDC (its highest point
during rotation), as shown in
Figures 54–55.
7. Use outfeed table lever to set outfeed table
so knife or insert barely touches straightedge,
as shown in
Figure 55.
Calibrating
1
⁄
8
" Infeed
Table Stop
The infeed table on the Model G0857/G0858 has
a built-in table stop that automatically sets depth
of cut at
1
⁄
8
". It is necessary to adjust this stop if
you adjust table parallelism.
Item(s) Needed: Qty
Precision Straightedge 3' .................................. 1
Tape Measure .................................................... 1
Hex Wrench 5mm .............................................. 1
To calibrate the
1
⁄
8
" infeed table stop:
1. DISCONNECT MACHINE FROM POWER!
2. Remove table release knob by unthreading
it (see
Figure 56), and then remove infeed
table covers (see
Figure 56) by removing
plugs and cap screws that secure covers to
table.
Checking Adjusting 1/8 Infeed Table Stop
Figure 56. Accessing infeed table stop.
Table Cover
Access Holes
for Cap Screws
Knob Removed
from Stop
Summary of Contents for G0857