5.1 Setting operating mode

By using the infrared remote control AL1321 it is possible to select one of the following operating mode.

• DMX512 signal control mode

Each fixture is controlled from DMX512 signal control.

• MASTER-SLAVE or AUTOMATIC mode

The projector operates independently, without DMX512 signal control.

(see chapter 

6.0 MASTER/SLAVE and AUTOMATIC function

)

• FIXED COLOURS mode

The projector operates independently, without DMX512 signal control.

(see chapter 

7.0 FIXED COLOURS function

)

Every button push is confirmed by a very short flash coming from the projector.

The following buttons will be used:

5.2 Setting DMX Address

By using the remote control (AL1321) it is possible to select the DMX address and mode:

5.0 Use of the unit

AV

TELETEXT

1-/--

AV

79ʗ

.....

1

0

PROG +

PROG -

P+

P-

Warning! 

Before performing any setting operation it is necessary to log in as reported in the chart below.

Function

Buttons

Description

LOGIN

1

2

3

It is the first procedure to be performed. After pushing the buttons 1, 2, 3  it is pos-

sible to access the functions settings. The function is confirmed by 1 white flash

coming from the projector.  

LOGOUT

/

The logout is automatic after 5 minutes of missing reception of the signal coming

from the remote control. Once th projector logs out it is not possible to perform

any other operation before a new login.

Funzione

Tasti

Descrizione

Change

of DMX

mode

+ 1 /.../ 6

Select the nuber of DMX channels. If the setting is correct then the projector will

confirm the procedure by performing 2 white flashes. (e.g. Projector RGBW 5

channels, press 5)

Change

of DMX

address

+  0....9 

79ʗ

The new entered address must feature 3 digits (e.g. 0 6 7). If the address is correct

then the projector will confirm the procedure by performing 3 white flashes

Summary of Contents for RB250

Page 1: ...Ruby MC Manuale di istruzioni Instructions manual...

Page 2: ...5 5 2 DMX functions with DMX MODE 5 channels 23 5 5 3 DMX functions with DMX MODE 6 channels 24 5 6 DMX functions Dynamic white 24 5 6 1 DMX functions with DMX MODE 2 channels 24 5 6 2 DMX functions w...

Page 3: ...to a qualified technician for any regular maintenance action not described in this manual 1 1 2 Installation The unit installation actions must be performed by a qualified staff 1 1 3 Protection again...

Page 4: ...it 2 0 Size 250mm 9 83in 289mm 11 37in 1 0 5 m m 0 4 1 i n 6 5 m m 0 2 6 i n 2 36in 155mm 6 12in 164mm 6 46in 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of...

Page 5: ...operate in any position Use the holes 12 5 1 2 or 6 5 1 4 in the bracket to fix the unit 4 2 Adjusting light beam direction 1 Untighten the lateral screw 4 2 Rotate the bodies of the unit towards des...

Page 6: ...supplies features are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as pres...

Page 7: ...OG PROG P P Warning Before performing any setting operation it is necessary to log in as reported in the chart below Function Buttons Description LOGIN 1 2 3 It is the first procedure to be performed...

Page 8: ...lue Description 1 Red 0 255 Proportional control 0 100 of the Red color 2 Green 0 255 Proportional control 0 100 of the Green color 3 Blue 0 255 Proportional control 0 100 of the Blue color 4 White 0...

Page 9: ...hannel Function Value Description 1 Warm white 0 255 Proportional control 0 100 of the warm white 2 Cold white 0 255 Proportional control 0 100 of the cold white 3 Dimmer Strobo 0 15 Luminous output i...

Page 10: ...lowing picture shows an example of a Master Slave layout Attention In absence of DMX signal the led will remain ON Channel Function Value Description 1 Dimmer Strobe 0 15 Luminous output intensity 100...

Page 11: ...nta red yellow white The pre set time of each scene is 5 seconds If the projector is turned off when it is set in automatic mode it will switch on again in automatic mode with the same se lected scene...

Page 12: ...projector is on if required by the weather conditions the glass is automatically warmed up If the projection is to be started at a definite time take care to defrost the glass in advance so that the l...

Page 13: ...these instructions 11 1 Cleaning the unit The unit must be cleaned regularly Cleaning regularity will depend especially on the environment where the unit will operate deposits of dust smokes or other...

Page 14: ...ibile Cause Action The unit does not respond properly to the DMX control Incorrect DMX cable connection Check connections and wires Rectify inefficient connec tions Repair or replace damaged wires Unf...

Page 15: ...nal current 0 26A 230V Maximum power 57W Thermal protection Electronic Light output source Type of light output source 6 Leds Optics Optical system Lenses Control Protocol USITT DMX 512 Control channe...

Page 16: ...English 31...

Page 17: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 1...

Reviews: