4.3 Connection to mains power

The unit can operate with voltage from 100 to 277Vac and with frequency of 50 and 60Hz.

For the connection use main cable in the side of the rear boxl of the fixture and connect as shown below.

4.4 Connection to DMX signal

The DMX signal is to be connected by using a shielded cable designed for devices RS-485.

The signal cable must be connected according to the following table:

GND = Shield

DATA - = Black

DATA + = Red

The projector is fitted with butt connectors and heat shrink tube which allow to perform 

IP67

connections.

To make the connection follow these instructions.

Warning!

• Before connecting the unit, verify that power supplies features are compatible with the unit features.

• The unit must never be installed if not grounded electrically.

• It is suggested to use a magnetothermic switch along the power supply line, as prescribed by in force rules.

• The unit must not be powered up through a dimmer power device.

• Wiring and connection actions are to be performed by a qualified staff.

Live

Ground

Neutral

Brown

Yellow Green

Blue

Main supply

Warning!

Follow the instructions provided along with the connection kit to perform the connections.

Warning!

All data wires must be isolated one from another and from the shield.

The GND of the DMX signal is not to be connected to the electric ground of the unit.

Insert a terminal plug with a 120 Ω resistor connected to DATA- and DATA+ in the last unit.

Warning!

Follow the instructions provided along with the connection kit to perform the connections.

Summary of Contents for Jasper AL4360

Page 1: ...Jasper AL4360 Manuale di istruzioni Instructions manual...

Page 2: ...with DMX MODE 5 channels 21 5 5 3 DMX functions with DMX MODE 6 channels 21 5 6 DMX functions Dynamic white 22 5 6 1 DMX functions with DMX MODE 2 channels 22 5 6 2 DMX functions with DMX MODE 3 chann...

Page 3: ...ied technician for any regular maintenance action not described in this manual 1 1 2 Installation The unit installation actions must be performed by a qualified staff 1 1 3 Protection against burns an...

Page 4: ...19 1 2 495 17 3 4 450 18 3 4 477 3 1 8 80 5 5 8 142 15 4 3 4 120 3 8 1 0 5 0 1 4 6 5 0 1 4 6 5 0 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of goods to the...

Page 5: ...n operate in any position Use the holes 10 5 3 8 or 6 5 1 4 in the bracket to fix the unit 4 2 Adjusting light beam direction 1 Untighten the lateral screw 1 2 Rotate the bodies of the unit towards de...

Page 6: ...supplies features are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as pres...

Page 7: ...er to the manual of the accessory 5 0 Use of the unit AV TELETEXT 1 AV 79 1 0 PROG PROG P P Warning Before performing any setting operation it is necessary to log in as reported in the chart below Fun...

Page 8: ...olor 3 Blue 0 255 Proportional control 0 100 of the Blue color 4 White 0 255 Proportional control 0 100 of the White color 5 Dimmer Strobe 0 15 Luminous output intensity 100 16 150 Proportional contro...

Page 9: ...160 Luminous output intensity 0 161 255 Proportional control of the strobe effect 0 100 255 max Channel Function Value Description 1 Warm white 0 255 Proportional control 0 100 of the warm white 2 Col...

Page 10: ...ction RGBW and DW MASTER SLAVE 1 SLAVE N IN OUT IN OUT SLAVE 2 IN OUT Terminal resistor R 120 not included Funzione Tasti Descrizione Master Con figuration AV the input or the removing of the automati...

Page 11: ...the TV key Colour se lection 1 2 3 4 Select the colour whose intensity is intended to be adjusted by the keys from 1 to 4 1 red 2 green 3 blue 4 white Colour intensity The intensity of the selected c...

Page 12: ...to be started at a definite time take care to defrost the glass in advance so that the leds can be lit at the time required With very cold temperatures below 20 C we recommend you to let the projector...

Page 13: ...sistance centres easier specify serial number and model of the unit which spare parts are requested for Inconvenience Possibile Cause Action The unit does not respond properly to the DMX control Incor...

Page 14: ...ir old appliance Mechanical features Height 495mm 19 1 2 Width 477mm 18 3 4 Depth 142mm 5 5 8 Weight 18Kg 39 7Lbs Thermal features Minimum ambient temperature 40 C 40 F Maximum ambient temperature 50...

Page 15: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 1...

Reviews: