1.1 Safety information

1.1.1 Protecting against electric shock

• Disconnect the unit from mains supply before servicing it or performing any other action.

• Always ground/earth the unit electrically.

• Before connecting the unit to power supplies, verify that operating voltage and frequency are compatible.

• Do not handle the unit with wet hands or in the presence of water.

• Check regularly that the power supply cable is not damaged or crushed.

• Apply to a qualified technician for any regular maintenance action not described in this manual.

1.1.2 Installation

• Fix the unit with screws, hooks or any other support able to bear the weight of the unit itself.

• The unit installation actions must be performed by a qualified staff.

1.1.3 Protection against burns and fire

• 

Suitable to be installed onto normally inflammable surfaces.

• The unit is not to be installed in places where the ambient temperature exceeds 50° (122°F).

1.1.4 Weather protection

The unit is classified as device with an IP66 weather protection rate.

1.2 Compliance

• Product in compliance with EN60598-1 EN60598-2-17.

• Product in compliance with 2002/95/CE (RoHS).

1.0 Introduction

Warning!

This unit is suitable for professional use only, not for domestic use.

Summary of Contents for Jade 16 AL4050

Page 1: ...Jade 16 AL4050 Manuale di istruzioni Instructions manual...

Page 2: ...ions with DMX MODE 5 channels 21 5 3 3 DMX functions with DMX MODE 6 channels 21 5 4 DMX functions Dynamic white 22 5 4 1 DMX functions with DMX MODE 2 channels 22 5 4 2 DMX functions with DMX MODE 3...

Page 3: ...action not described in this manual 1 1 2 Installation Fix the unit with screws hooks or any other support able to bear the weight of the unit itself The unit installation actions must be performed by...

Page 4: ...e unit 2 0 Size 116mm 4 57 114mm 4 47 194mm 7 62 8 m m 0 3 1 9 m m 0 3 3 19mm 0 76 114mm 4 47 160mm 6 30 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of goods...

Page 5: ...bile structure truss To fix the unit onto a supporting structure or truss it is suggested to use hooks 4 type Aliscaff The hooks are to be fitted to the unit through the holes in the bracket as shown...

Page 6: ...electrically It is suggested to use a magnetothermic switch along the power supply line as prescribed by in force rules The unit must not be powered up through a dimmer power device Wiring and connec...

Page 7: ...med After pushing the buttons 1 2 3 it is pos sible to access the functions settings The function is confirmed by 1 white flash coming from the projector LOGOUT The logout is automatic after 5 minutes...

Page 8: ...oportional control 0 100 of the Blue color 4 White 0 255 Proportional control 0 100 of the White color 5 Dimmer Strobe 0 15 Luminous output intensity 100 16 150 Proportional control of the luminous ou...

Page 9: ...output intensity 0 161 255 Proportional control of the strobe effect 0 100 255 max Channel Function Value Description 1 Warm white 0 255 Proportional control 0 100 of the warm white 2 Cold white 0 25...

Page 10: ...uration Dynamic white To set up the unit as SLAVE set the 3 channels DMX mode with address 001 MASTER SLAVE 1 SLAVE N IN OUT IN OUT SLAVE 2 IN OUT Terminal resistor R 120 not included 6 0 Master Slave...

Page 11: ...mode is activated or deactivated by the TV key Colour selection 1 2 3 4 Select the colour whose intensity is intended to be adjusted by the keys from 1 to 4 1 red 2 green 3 blue 4 white Colour intensi...

Page 12: ...lly on the environment where the unit will operate deposits of dust smokes or other wastes will reduce the light output performances Clean regularly the glass of the unit Be careful when cleaning the...

Page 13: ...on of the firmware in use on the projector is displayed Temperature The LEDs operating temperature value is displayed The European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEE...

Page 14: ...espond properly to the DMX control Incorrect DMX cable connection Check connections and wires Rectify inefficient connec tions Repair or replace damaged wires Unfinished data connection Insert a termi...

Page 15: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 1...