Inconvenience
Possibile Cause
Action
The fixture is com-
pletely dead
No power to fixture.
Check that power is switched on and cables are
plugged in.
PAN and TILT block not
removed.
Check the transport locks.
PCB communication error Check if the unit display visualizes error messages
The unit does not
respond properly
to the DMX control.
Incorrect DMX cable
connection.
Check connections and wires. Rectify inefficient
connections. Repair or replace damaged wires.
Unfinished data
connection.
Insert a terminal plug in the output jack of the last unit of
the connection.
Incorrect address
assignment to the units.
Check the addresses of the units and the protocol
settings.
One of the unit is faulty
and it is affecting the
data transmission along
the connection.
Short-circuit units singularly, one by one, since regular
working is restored.
PCB communication error Check if the unit display visualizes error messages
No light output
Lamp blown
Disconnect fixture and replace lamp.
Lamp not installed
Disconnect fixture and install lamp.
Lamp access safety
switch open
Verify that frontal panel is fully seated and locked in
place.
The electronic ballast is in
alarm status.
Check the electronic ballast display, verify the type of
alarm and, if the display visualizes the alarm
e 1
, turn off
the unit and Let the fixture cool down.
Lamp cuts out
intermittently.
Fixture is too hot.
Let the fixture cool down.
Check that the air vents above the cooling fans are not
obstructed and that the fans are working correctly.
Ensure that the ambient temperature is below 35 °C.
17.0 Troubleshooting
English
49