7.1 Lamp specifications
Globe MK2 4000
is designed exclusively for use with XStage 4000 W.
The lamps are part of the Xeno family of discharge lamps and must be handled with great care. The lamp oper-
ates at high pressure, and the slight risk of explosion of the lamp exists if operated over its recommended life. We
recommend, therefore, that the lamp be replaced within the manufacturer’s specified lamp life.
At every lamp change, reset the lamp life counter using the unit control panel. This help you to remember when
replacing the lamp.
The lamp specification, available via your
Griven
distributor, are shown in the table below.
7.2 Lamp installation
In order to carry out the operation comfortably, we suggest to lock the PAN and TILT movement of the fixture, as
previously described.
Attention!
Disconnect the unit from mains supply before servicing it or performing any other action.
The lamp is very hot during operations! Wait at least for 30 minutes before changing.
Wear all necessary protective garments to handle the Xenon lamp (gloves, protective mask, etc.)
Lamp is to be replaced exclusively with the unit positioned vertically, as per following picture.
Lamp
OSRAM XStage 4000 W
Griven code
LP1026
Rated lamp wattage
4000W
Rated lamp voltage
30V
Rated lamp current
130A
Current control range
80A - 135A
Ignition voltage
36.000V
Luminous flux
150.000 lm
Average service life
1000 h
Base (cathode)
SFc 28-27
Base (anode)
SFaX 27-9.5
Attention!
Installing any other lamp may create a safety hazard or damage the fixture!
7.0 Lamp installation and replacement