3.4 DMX connection
The connection of the XLR 3 poles must be as follows:
pin 1---> function GND (SHIELD)
pin 2---> function SIGNAL -
pin 3---> function
Pls. ensure that the cables are properly connected.
Use shielded cable.
4.0 USE OF THE PROJECTOR
4.1 Switching on the unit
Connect the unit to power supply and turn the main switch on, The unit can work in dmx mode
.
The lamp should switch on within 2 seconds from the ignition of the unit. (7-pict.13). Should the lamp not switch on, the operation
will be automatically repeat 3 times
4.2 Control panel
The control panel is located at the bottom of the unit
When the unit is turned on, the display shows the DMX addresses (initially 001) sequentially, and indicates the presence of the
DMX signal.
16
pict.14
Hose
Data +
Data -
GND
Min. sect.
0.35 mm