Jupiter Rev. 4.0
page 6 of 10
551115
For further details consult the configuration schemes available on our website.
B
DMX IN
DMX OUT
DMX Chain configuration - S type cable
DMX IN
DMX OUT
DMX IN
DMX OUT
DMX IN
DMX OUT
DMX IN
DMX OUT
Single Chain configuration - C type cable
C
A
B
E
dmx
D
G
A
Max.
10A
per
daisy chain
Multi Chain configuration using DMX Junction Box - C type cable
C
A
B
E
dmx
D
C
A
F
A
B
E
dmx
D
I
I
I
I
DMX/RDM Controller
Start Line Box
Code: AL5058C
Code: AL0512
Code: AL5059C
A
B
C
D
E
F
G
H
Power Input
Jupiter, Jupiter MC
DMX Cable
DMX Junction Box
Connection Cable
Junction Box (Not Included) Minimun IP Rating: IP67 / Scatola di giunzione (non inclusa) Grado IP minimo: IP67
AL8264 L=1m (3 ft) AL8265 L=2m (6 ft) AL8266 L=3m
(10 ft) AL8267 L=5m (16 ft) AL8268 L=10m (32 ft)
CABLE/CAVI
Brown/Marrone
Blue/Blu
Yellow/Green
Red/Rosso
Black/Nero
White/Bianco
USE/UTILIZZO
Live/Fase
Neutral/Neutro
Ground
DMX Data +
DMX Data -
DMX GND
DMX cable type:
Use a DMX repeater on each
32nd
fixture of the
daisy chain or in case the total DMX LINE length
exceeds 300m (1000 ft)
I
DMX Terminator
Code: AL5169
H
H
D
A
A
A
A
Utilizzare un ripetitore DMX ogni
32
apparecchi
della catena o se la lunghezza totale della LINEA
DMX supera i 300 m (1000 piedi)
2x0.34 mm2 impedance 110Ω,
capacity 43pF/m, resistance 50Ω/Km.
Tipo di cavo DMX:
Max.
10A
per
catena
120Ω RESISTANCE
120Ω RESISTANCE
Configurazione DMX - Tipo di cavo S
RESISTENZA 120Ω
RESISTENZA 120Ω
Configurazione catena singola - Tipo di cavo C
Configurazione multi catena utilizzando una scatola di giunzione per DMX - Tipo di cavo C
Single Chain configuration - M type cable
Configurazione catena singola - Tipo di cavo M
Junction Box
(Not supplied by Griven)
(Minimum IP Rating: IP67)
I
Scatola di giunzione
(Non fornito da Griven)
(Classificazione IP minima: IP67)
Controller DMX/RDM
Start Line Box
Ingresso alimentazione
Jupiter, Jupiter MC
Cavo DMX
Scatola di giunzione DMX
Cavo di collegamento
DMX Terminator
Giallo / Verde
Terra
2x0,34 mm2 impedenza 110Ω,
capacità 43pF / m, resistenza 50Ω / Km.
DMX/RDM Controller
Code: AL0512
A
B
D
E
Power Input
Jupiter, Jupiter MC
DMX Cable
Junction Box (Not supplied by Griven) Minimun IP Rating: IP67
CABLE
Brown
Blue
Yellow/Green
Red
Black
White
USE
Live
Neutral
Ground
DMX Data +
DMX Data -
DMX GND
I
Max.
10A
per
daisy chain
DMX cable type:
Use a DMX repeater on each fixture of the daisy
chain or in case the total DMX LINE length
exceeds 300m (1000 ft)
Utilizzare un ripetitore DMX su ogni apparecchio
nel collegamento in serie o se la lunghezza totale
della LINEA DMX supera i 300 m (1000 piedi)
2x0.34 mm2 impedance 110Ω,
capacity 43pF/m, resistance 50Ω/Km.
Tipo di cavo DMX:
2x0,34 mm2 impedenza 110Ω,
capacità 43pF / m, resistenza 50Ω / Km.
Max.
10A
per
collegamenti
in serie
DMX/RDM Controller
Code: AL0512
A
B
D
E
Power Input
Jupiter, Jupiter MC
DMX Cable
I
DALI
J
DALI IN
DALI OUT
Configurazione DALI
DALI IN
DALI OUT
DALI IN
DALI OUT
DALI IN
DALI OUT
DALI IN
A
D
A
A
A
A
J
DALI Controller
Max.
10A
per
daisy chain
DMX cable type:
Use a DMX repeater on each
32nd
fixture of the
daisy chain or in case the total DMX LINE length
exceeds 300m (1000 ft)
Utilizzare un ripetitore DMX ogni
32
apparecchi
della catena o se la lunghezza totale della LINEA
DMX supera i 300 m (1000 piedi)
2x0.34 mm2 impedance 110Ω,
capacity 43pF/m, resistance 50Ω/Km.
Tipo di cavo DMX:
2x0,34 mm2 impedenza 110Ω,
capacità 43pF / m, resistenza 50Ω / Km.
Max.
10A
per
catena
CABLE/CAVI
Brown/Marrone
Blue/Blu
Yellow/Green
Red/Rosso
Black/Nero
White/Bianco
USE/UTILIZZO
Live/Fase
Neutral/Neutro
Ground
DMX Data +
DMX Data -
DMX GND
Giallo / Verde
Terra
Controller DMX/RDM
Ingresso alimentazione
Jupiter, Jupiter MC
Cavo DMX
Controller DALI
Junction Box (Not Included) Minimun IP Rating: IP67 / Scatola di giunzione (non inclusa) Grado IP minimo: IP67
DALI Chain configuration
Monocavo
Cavi
Dedicati
RED = DMX +
BLACK = DMX -
WHITE = COMMON
MARRONE = L (Fase)
BLUE = N (Neutral)
YELLOW / GREEN = GND
ROSSO = DMX +
BIANCO = COMMON
NERO = DMX -
BROWN = L (Live)
BLU = N (Neutro)
GIALLO / VERDE = GND
WHITE = COMMON
BIANCO = COMMON
BLACK = DMX -
NERO = DMX -
RED = DMX +
ROSSO = DMX +
MARRONE = L (Fase)
BLUE = N (Neutral)
YELLOW / GREEN = GND
BROWN = L (Live)
BLU = N (Neutro)
GIALLO / VERDE = GND
Monocavo
Cavi
Dedicati
RED = DMX +
BLACK = DMX -
WHITE = COMMON
MARRONE = L (Fase)
BLUE = N (Neutral)
YELLOW / GREEN = GND
ROSSO = DMX +
BIANCO = COMMON
NERO = DMX -
BROWN = L (Live)
BLU = N (Neutro)
GIALLO / VERDE = GND
WHITE = COMMON
BIANCO = COMMON
BLACK = DMX -
NERO = DMX -
RED = DMX +
ROSSO = DMX +
MARRONE = L (Fase)
BLUE = N (Neutral)
YELLOW / GREEN = GND
BROWN = L (Live)
BLU = N (Neutro)
GIALLO / VERDE = GND
Connection Detail (M type cable) - Monocable Connection
Connection Detail (M type cable) - Separate Cables Connection
Combined/Combinati
Power + Data cable
Power cable
DMX cable
Per maggiori dettagli consultare gli schemi di configurazione disponibili sul nostro sito.
DMX/RDM Controller
Code: AL0512
A
B
D
E
Power Input
Jupiter, Jupiter MC
DMX Cable
Junction Box (Not supplied by Griven) Minimun IP Rating: IP67
CABLE
Brown
Blue
Yellow/Green
Red
Black
White
USE
Live
Neutral
Ground
DMX Data +
DMX Data -
DMX GND
I
Max.
10A
per
daisy chain
DMX cable type:
Use a DMX repeater on each fixture of the daisy
chain or in case the total DMX LINE length
exceeds 300m (1000 ft)
Utilizzare un ripetitore DMX su ogni apparecchio
nel collegamento in serie o se la lunghezza totale
della LINEA DMX supera i 300 m (1000 piedi)
2x0.34 mm2 impedance 110Ω,
capacity 43pF/m, resistance 50Ω/Km.
Tipo di cavo DMX:
2x0,34 mm2 impedenza 110Ω,
capacità 43pF / m, resistenza 50Ω / Km.
Max.
10A
per
collegamenti
in serie
DMX/RDM Controller
Code: AL0512
A
B
D
E
Power Input
Jupiter, Jupiter MC
DMX Cable
I
DALI
J
DALI IN
DALI OUT
Configurazione DALI
DALI IN
DALI OUT
DALI IN
DALI OUT
DALI IN
DALI OUT
DALI IN
A
D
A
A
A
A
J
DALI Controller
Max.
10A
per
daisy chain
DMX cable type:
Use a DMX repeater on each
32nd
fixture of the
daisy chain or in case the total DMX LINE length
exceeds 300m (1000 ft)
Utilizzare un ripetitore DMX ogni
32
apparecchi
della catena o se la lunghezza totale della LINEA
DMX supera i 300 m (1000 piedi)
2x0.34 mm2 impedance 110Ω,
capacity 43pF/m, resistance 50Ω/Km.
Tipo di cavo DMX:
2x0,34 mm2 impedenza 110Ω,
capacità 43pF / m, resistenza 50Ω / Km.
Max.
10A
per
catena
CABLE/CAVI
Brown/Marrone
Blue/Blu
Yellow/Green
Red/Rosso
Black/Nero
White/Bianco
USE/UTILIZZO
Live/Fase
Neutral/Neutro
Ground
DMX Data +
DMX Data -
DMX GND
Giallo / Verde
Terra
Controller DMX/RDM
Ingresso alimentazione
Jupiter, Jupiter MC
Cavo DMX
Controller DALI
Junction Box (Not Included) Minimun IP Rating: IP67 / Scatola di giunzione (non inclusa) Grado IP minimo: IP67
DALI Chain configuration
Dettaglio connessione (Cavo tipo M) - Monocavo
Dettaglio conessione (Cavo tipo M) - Collegamento dei cavi separato
DMX Configurations / Configurazioni DMX