Please read and understand instructions before attempting installation 

 

Grifco MinEB Users Manual 

 

 

 

 

 

MinEB installation and users manual 

Rev: 602140 

 

Contents: 

Introduction 

 

Page 1 

 

MinEB layout 

 

Installation 

Installing the MinEB 

Page 2 

Trigger input 
Relay output 
 

Installation Examples 

Dock Leveller 
Alarm system emergency close 
 

Page 3 

Warranty / Guarantee 

 

Page 4 

 

Grifco Advanced Users 

QUICK START GUIDE 

 

INSTALLING 
• Remove power 
• Remove lid 
• Install MinEB into EXPANSION socket on MCB 
• Adjust dipswitches 
• Replace lid and resume power 
 
 
DIPSWITCHES 
Trigger Input Functions: 
 

 

Relay Settings: 

 

For a more detailed explanation on installation, setup, 

and operation please read booklet 

 

Dipswitch 1 

Dipswitch 8 

Trigger Action 

OFF 

OFF 

Operator closes to closed limit 

ON 

OFF 

Operator opens to open limit 

OFF 

ON 

Operator is isolated if 24V is applied 

to the trigger 

ON 

ON 

Operator is isolated when no voltage 

is applied. 

SW2  SW3  SW4  SW5  SW6  SW7 

Relay Behaviour 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

Closed position 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

Opened more then 50% 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

When not closed 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

While running 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

While r1 min 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

While running 1Hz 

 
Introduction 

Congratulations on your purchase of the Grifco MinEB. The MinEB is a low cost logic upgrade designed to easily provide 
extra features to the Maestro Operator. Its features include a relay output with adjustable behaviours, and an auxiliary 
OPEN\CLOSE trigger input.   
 
It is the perfect solution for connecting a simple peripheral device to the Maestro operator, such as a dock leveller, alarm 
switchboard, hazard lights, and many more. 

 