D-M-ACG-122 D-Drive Relay Expansion 

Module Manual

 

6

 

2-Aug-22 

 

6.  Installation 

6.1.  Single Relay Module DDEB-1R 

Plug the White MOLEX connector on the relay module onto the M2A Header connector of the DDI-07, 

DDI-12 or DDI-15. 

6.2.  Six Relay Module DDEB-6R 

Parts provided in the kit are shown below. 
 

  

1.  Mount the 4 spacers (E) on the expansion board using the 4 screws (B) (shown below) 

 

2.  Connect one end of the cable (F) to the connection X30a on the relay module. Connect other end of 

cable (F) to the connection X30a on the DDI-07, DDI-12 or DDI-15 controller circuit board. 

 

3.  Activate the expansion board via the controller by setting parameter P.800 to 8. 
 

 

Summary of Contents for DDEB-1R

Page 1: ...dels DDI 07 DDI 12 and DDI 15 This manual should be read in conjunction with Installation Manual D Drive Wall Control Manual D M ACG 100 Chamberlain Australia Pty Ltd Unit 1 75 Epping Road North Ryde...

Page 2: ...children to operate push button s or remote transmitter s Serious personal injury from a closing commercial door may result from misuse of the operator Activate operator only when the door is in full...

Page 3: ...Safety Warnings 2 2 Contents 3 3 General Information 4 4 Schematic Drawings 4 4 1 Single Relay Module DDEB 1R 4 4 2 Six Relay Module DDEB 6R 4 5 Specifications 5 6 Installation 6 6 1 Single Relay Modu...

Page 4: ...trollers DDI 07 DDI 12 and DDI 15 These provide an additional 1 or 6 relay outputs dependant on model The modules can be used on D Drive Wall Controller Variable Speed Inverter Controllers DDI 07 DDI...

Page 5: ...VDC typ 15 mA max 26 VDC 20 mA All inputs must be connected potential free or 4 V inactive for logical 0 16 V active for logical 1 min duration of input control commands 100 ms Relay Output Normally...

Page 6: ...5 6 2 Six Relay Module DDEB 6R Parts provided in the kit are shown below 1 Mount the 4 spacers E on the expansion board using the 4 screws B shown below 2 Connect one end of the cable F to the connect...

Page 7: ...ive during opening in End position OPEN and during locking in end open position 0606 Synchronous control CLOSE signal duration 0 5 seconds The output is active during Closing in End position Close and...

Page 8: ...earance time ON in end position OPEN 1298 Direction dependent red traffic light On for opening and closing movement Off when CLOSED and when OPEN Flashes during evacuation time 12AD Direction independ...

Page 9: ...Expansion Module Manual 9 2 Aug 22 Chamberlain Australia Pty Ltd Unit 1 75 Epping Road North Ryde NSW 2113 Ph 1800 GRIFCO Chamberlain New Zealand Ltd 17B Arrenway Drive Rosedale 0623 Auckland Ph 0800...

Page 10: ...D M ACG 122 D Drive Relay Expansion Module Manual 10 2 Aug 22 www grifco com au...

Reviews: