45
14. COMMON INFORMATION F CODES
CODE
DESCRIPTION
REASON FOR ERROR AND FIX
F.000 Door position too far up
•
Too small a parameter value for upper emergency limit switch → increase P.239
•
Upper limit switch range (limit switch band) too small → increase P.233
•
Mechanical brake defective or improperly set
F.005 Outside door position too far down
•
Too small a parameter value for lower emergency limit switch → increase P. 229
•
Lower limit switch range (limit switch band) too small → increase P. 223
•
Mechanical brake defective or improperly set
F.020 Run time exceeded (during
opening, closing or deadman)
•
Current motor run time has exceeded set maximum run time (P.410 (Opening),
P. 415 (Closing), P.419 (Deadman move)), door may be sticking or is blocked.
•
Door is blocked
•
If using mechanical limit switches, one may not have tripped
F.030 Lag error (position change of the
door is less than expected)
•
Door or motor is blocked
•
Insufficient power for providing necessary torque
•
Too little speed
•
Mechanical limit switch was not left or is defective
•
Incremental or absolute encoder shaft is slipping
•
Wrong positioning system selected (P.205)
•
One motor phase is missing
•
The brake does not release
•
Settings of the failure detecting time are not correct (P.430 or P.450)
F.031 Detected rotational direction
deviates from expected
•
When using incremental encoders: Channel A and B reversed
•
Motor rotation direction reversed compared with calibration setting → teach in
the limits new (P.210 = 5)
•
Too much „pancaking“ when starting, brake releases too soon, or too little
torque, adjust boost (P.140 or P.145) as necessary.
F.211 External E-Stop 1 tripped
•
E-Stop chain was interrupted starting at Input 1
•
Check possible Safety Brake activation
•
Check manual hauling chain engagement
•
Check external safety brake or wire link on Pins 41 and 42
F.212 External E-Stop 2 tripped
•
E-Stop chain was interrupted starting at Input 2
•
Check possible Safety Brake activation
•
Check kostal encoder operation
F.360 Redundancy error with short circuit •
Short circuit detected on edges with normally closed contact
•
The light beam of the optical edge is interrupted
•
Jumper for 1K2 / 8K2 is wrong set
F.361 Number of trips of the Safety input
D, normally this is the integrated
safety edge evaluation, has
reached set limit (configurable in
P.46E)
•
Parameterized, maximum number of trips of the safety input D during a door
cycle was exceeded → To reset close the door
•
In deadman mode
•
Check the set number of trips in P.46E
F.362 Redundancy error with short circuit •
One of the processing channels for short circuit detection does not react
identically with the second channel → Controller
•
board defective, if no other error message F.3xx is shown
•
Dynamical optical safety edge connected but not set in Parameter P.460
F.363 Interruption on edge input
•
Connection cable defective or not connected
•
Termination resistor incorrect or missing
•
Jumper 1K2 / 8K2 incorrectly set
F.364 Safety edge – testing failed
•
Safety edge was not activated as expected when requesting a test.
•
The time between request for testing and actual testing not in agreement
•
The pre-limit switch is set incorrectly
F.365 Redundancy error with interruption
•
One of the processing channels for interruption detection does not react
identically with the second channel → Controller
•
Board defective, if no other error message F.3xx is shown
•
Dynamic optical system connected but not set in Parameter P.460