38
9. COMMISSIONING
9.11 SETTING UP A PROGRAMMABLE INPUT
INPUT
PIN
PARAMETER
DDC-22 DEFAULT
DDI DEFAULT
1
52
P.501
0101
0101
2
53
P.502
0402
0402
3
54
P.503
0701
0701
4
72
P.504
0201
0201
5
75
P.505
0520
0520
6
82
P.506
0301
0301
7
85
P.507
0601
0601
8
61
P.508
0801
0802
9
64
P.509
0903
1003
10
65
P.50A
1001
1001
VALUE
FUNCTION
VALUE
FUNCTION
0000
OFF (disable)
0701
CLOSE with clearance timer
0101
OPEN1 to full open position, with auto close &
clearance timers
0801
INTERLOCK IN CLOSED POSITION. No deadman
override.
0102
OPEN1 to part open position, with auto close &
clearance timers
0802
INTERLOCK in closed position. Deadman override
possible.
0106
OPEN2 to full open position from inside, with auto
close & clearance timers
0903
BYPASS Mid Limit
0110
OPEN1 to full open position from outside, with auto
close & clearance timers
1001
DISABLE auto close time
0201
IMPULSE open & close (reversing closing) with
auto close & clearance timers
1003
Disable intermediate stop, NO contact
0301
Permanent-OPEN, NO contact, 1. Intermediate
stop 2. OPEN, without hold open time, without
clearance time, both directions
1004
DISABLE commands from outside
0402
Stop-command, NO contact
1405
PHOTOCELL stop & reverse during opening, pause
when closing
0501
PHOTOCELL stop & reverse when closing
1422
SAFETY EDGE stop & when opening. Suitable for 8k2
Input only (e.g. Input 10)
0520
Safety: Reversing when CLOSING, NO contact,
with testing in end position OPEN
1612
SAFETY EDGE free ride when opening. Suitable for
8k2 Input only (e.g. Input 10)
0601
Manual operation for OPENING and CLOSING,
NO contact
1801
LOOP1 Loop detector parameter p.66x
Select the programmable Input Profile from the table below.