Appendix A Securing the ATM to the floor
To enhance the security of the equipment, it is recommended to secure the equipment to the floor
by using anchor bolts (not supplied with the equipment) as follows:
1.
Floor requirements
It is required to install the ATM on the concrete floor. Users should make sure the floor conforms
to the following requirements:
(1)
The concrete floor or base must be capable of withstanding the ATM.
(2)
In order to guarantee the ATM installation, the thickness of the concrete floor or base should
be ≥180mm (7.1 in.).
(3)
Make sure the concrete floor or base is as level as possible (please use the gradienter to verify
before installation).
(4)
It is required to drill anchor holes for anchor bolts. Please refer to section 4 in this chapter for
the positions of the holes.
2.
Fixing component specifications
4 M16*170mm anchor bolts are required for
installing the machine on the concrete floor.
Each anchor bolt consists of the following
components:
①
M16*170mm bolt;
②
M16 hex nut;
③
M16 spring washer (Φa=21.7mm,
Φi=16.5mm, T=3.7mm);
④
M16
washer
(Φa=40mm,
Φi=16.5mm, T=3mm);
⑤
M16*140mm expansion sleeve
Anchor bolt
3.
Tools
Fork-lift truck (manual or electric)
Vacuum cleaner
Cross screwdriver(Diameter: 6mm)
Gradienter
Pencil
Ratchet
wrench