MicroGuard
®
434/500 CALIBRATION MANUAL
TEL: 714) 259-9702 FAX: 714) 259-7626
12
OF
39
COMMAND 02 ZERO SENSOR
COMMAND 02 ZERO SENSOR
COMMAND 02 ZERO SENSOR
COMMAND 02 ZERO SENSOR
The Command 02 ZERO SENSOR permits the calibration of the zero of most analog sensors. Two sensors
can be zeroed using this Command. Each sensor is allocated a number that corresponds to the input to which
it is connected in the system.
THESE SENSORS INCLUDE:
1. Boom extension sensor, Analog input 2.
2. Boom angle sensor, Analog input 3.
The swing sensor has its own routine and is calibrated using Command 04.