background image

Water Technologies

Water Technologies

Water Technologies

Installation Instructions & Owner’s Manual

Advance Cabinet Series Softeners

Summary of Contents for GACS1035

Page 1: ...Water Technologies Water Technologies Water Technologies Installation Instructions Owner s Manual Advance Cabinet Series Softeners...

Page 2: ...Solids Over 10ppm may be harmful for human consumption Water conditioners do not remove nitrates or coliform bacteria this requires specialized equipment Greenway Water Conditioners are precision bui...

Page 3: ...the exit are incorporated If desired two regenerations within 24 hours are possible with a return to the preset program To do a double regeneration 1 Press the regen button once regen today will flas...

Page 4: ...to the building while not allowing water to exit from the system to the building Fig 3 This allows the service technician to draw brine and perform other tests without the test water going to the buil...

Page 5: ...be used to unscrew the nut or cap Do not use a pipe wrench to tighten nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer SITE REQUIREMENTS water pressure 30 100 psi curre...

Page 6: ...f the control valve form a 7 loop at the discharge end of the line so that the bottom of the loop is level with the drain connection on the control valve This will provide an adequate anti siphon trap...

Page 7: ...ss as calcium carbonate per gallon using the s or t buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon can be increased if soluble iron needs to...

Page 8: ...amming cont d 3 Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heav...

Page 9: ...ne tank filling and at no time during this process will you be without treated water 4 Power Loss If the power goes out for less than two hours the system will automatically reset itself If an extende...

Page 10: ...de Fig 3 on page 2 CAUTION If water flows too rapidly it could result in loss of media to the drain When the water is flowing steadily to the drain without the presence of air slowly open the inlet va...

Page 11: ...ay be needed for correct operation 2 Iron removal may vary depending on form of iron pH and other local conditions On waters that are pre chlorinated or where other pre oxidation occurs an iron precip...

Page 12: ...ation time option in programming E control set at NORMAL on 0 E check with regeneration time option in programming 5 Error followed by code Error code 1001 unable to recognize start of regeneration Er...

Page 13: ...and PC board power B no power at outlet B restore power C broken drive gear or drive cap assy C replace gear or drive cap assy D defective PC board D replace board 8 Valve does not regenerate automati...

Page 14: ...o Part No Description Qty 1 YY WS CV3005 Spacer stack assembly 1 2 YY WS CV3004 Drive cap assembly 1 3 YY WS CV3135 O ring 228 1 4a YY WS CV3011 Piston assembly downflow 1 4b YY WS CV3011 01 Piston as...

Page 15: ...ng 013 lower The injector plug and the injector each use one lower and one upper o ring REFILL PORT ASSEMBLY Item No Part No Description Qty 1 YY WS CV3195 01 Refill port plug assembly 1 2 YY WS CH461...

Page 16: ...CV3162 010 1 0 DLFC for 3 4 elbow YY WS CV3162 013 1 3 DLFC for 3 4 elbow YY WS CV3162 017 1 7 DLFC for 3 4 elbow YY WS CV3162 022 2 2 DLFC for 3 4 elbow YY WS CV3162 027 2 7 DLFC for 3 4 elbow YY WS...

Page 17: ...3 01 Meter plug assembly 1 SAFETY FLOAT ASSEMBLY Item No Part No Description 1 YY WS CH4650 01 474 safety elbow 3 8 2 YY WS CH4655 474 5 gpm flow control 3 YY WS CH4615 Elbow locking clip 4 YY WS CH46...

Page 18: ...connect 2 2 YY WS CV3150 Split ring 2 3 YY WS CV3105 O ring 215 2 4 YY WS CV3145 Bypass rotor 1 2 5 YY WS CV3146 Bypass cap 2 6 YY WS CV3147 Bypass handle 2 7 YY WS CV3148 Bypass rotor seal retainer...

Page 19: ...WS CV3189 Fitting 2 1 BRASS SWEAT Item No Part No Description Qty YY WS CV3007 02 1 brass sweat assembly 2 1 YY WS CV3151 Nut 1 quick connect 2 2 YY WS CV3150 Split Ring 2 3 YY WS CV3105 O ring 215 2...

Page 20: ...teps as shown to the right To access this mode press set clock 1 Accessed by pressing set clock 2 Adjust hours with and buttons AM PM toggles at 12 3 Press next 4 Adjust minutes with and buttons 5 Pre...