VECTRA SERIES

IMPORTANT SAFETY INSTRUCTIONS

WARNING 

– ALWAYS DISCONNECT THE UNIT 

BEFORE PERFORMING MAINTENANCE OR 
MAKING ANY CONNECTIONS. FAILURE TO 

DISCONNECT POWER COULD RESULT IN ELECTRICAL 
SHOCK OR DAMAGE, TO THE WALL CONTROL OR THE 
ELECTRONIC COMPONENTS. IT IS RECOMMENDED 
TO WEAR SAFETY GLASSES AND GLOVES WHILE 
PERFORMING THESE INSTRUCTIONS.

CAUTION 

– FOLLOW THE INSTRUCTION TO INSURE 

PROPER OPERATION AND FUNCTIONALITY OF THE 
CONTROL AND VENTILATION SYSTEM. – ONLY 
ONE WALL CONTROL PER VENTILATION SYSTEM IS 
POSSIBLE - KEEP WALL CONTROL LOW VOLTAGE WIRES 
MINIMUM 2FEET(610MM) AWAY FROM MOTORS, LIGHT 
BALLAST, DIMMERS AND   ELECTRICAL PANELS – DO 
NOT ROUTE WALL CONTROL LOW VOLTAGE WIRES 
ALONG SIDE HIGH VOLTAGE WIRES – MINIMUM WIRE 
REQUIREMENTS: LVT 18/4 CSA/UL. – THE DEFINED 
MAXIMUM LENGTH FOR THE WIRE CONNECTION IS 
250 FT (MAX).

MOUNTING THE VECTRA SERIES WALL 

CONTROLS (EHC 1.0 TC AND EHC 1.5 DC)

1) Unplug the ventilation system from main power source.
2) Installation with a single electrical junction box. Find a suitable 

location for the wall control that is free of obstructions. Using 

the electrical junction box, outline the box on the wall. Proceed 

to cut out the opening outlined on the wall.

3) Once the hole in the drywall is cut out, enter the wall control 

routed wires from the unit through the circular opening of the 

electrical junction box and push into place. Note: Always secure 

the junction box to a wall stud or by using electrical junction box 

side brackets. With a screw driver, secure the wall control wires 

to the electrical junction box with the built in clamp.

Note:

 The wall control can also be installed without 

using a electrical junction box, by simply cutting a 

2-7/8” by 1-1/3” at the desired location and securing it 

to the wall with wall anchors.(included)

4) Remove the insulation covering the end of the wire to expose 

the 4 wires, then strip the end of each individual wire.  With 

a screw driver connect each wire on the back of the control 

switch to its corresponding terminal. RED wire to “R” /  BLACK 

wire to “B1” / GREEN wire to “G” and WHITE wire to “W”. (Ref 

to figure 1.0)

5) Mount the wall control and install the Decora® wall plate.
6) Plug the ventilation system and proceed to test the wall control 

operation.

OPERATING THE 

VECTRA EHC 1.0 TC 

WALL CONTROL

POWER ON/OFF WALL CONTROL

Press the   button powers the wall control ON or OFF

Note:

 The default mode when powered ON is “VENT”

VENTILATION MODE SELECTION

Press the 

 button is the ventilation mode selector for your  

ventilation system, when the control is powered ON,

  = Friendly continuous ventilation energy savings 

mode

  = Continuous ventilation mode maximizes your 

indoor air quality

  = 20 min maximum speed / 40 min intermittent  

(the ventilation system is in stand-by mode) 

  = The ventilation system is powered OFF. (puts the 

unit in stand-by mode), it will respond to override 

controls. (If present)

 

OPERATING THE 

VECTRA EHC 1.5 DC 

WALL CONTROL

 

= Continuous ventilation mode maximizes 

your indoor air quality

 

= Friendly continuous ventilation energy 

savings mode

 = Recirculation ventilation mode (compatible 

with SS3.12 DD, DH 7.15 and XDH 7.15 only)

 = 20 min continuous ventilation /  

40 min intermittent (standby) mode 

 = 20 min continuous ventilation / 

  40 min recirculation mode 

 

= Humidistat override mode

 

= Maximum ventilation speed

 

= Medium ventilation speed

 

= Minimum ventilation speed

 

= The ventilation system is powered OFF. 

(puts the unit in stand-by mode), it will 

respond to override controls. (If present)

POWER ON/OFF WALL CONTROL

-   Press and hold the 

OK

 button for 3 seconds to power  

“ON” the wall control. 

Note: 

The factory default values are: “VENT MODE / 

MED SPEED”

-   Press and hold the 

OK

 button for 3 seconds to power  

“OFF” the wall control.

VENTILATION MODE SELECTION

-  Press the 

OK

 button to enable the selection menu for the 

ventilation operating mode.

-  Press the 

 ▲

 or 

 ▼

 

button to select the ventilation 

modes: VENT - 20MIN/HR – RECIRC or RECIRC-20 MIN/HR 

the selected ventilation mode value will flash. 

-  Press the 

OK

 button to select the desired ventilation mode. 

The wall control will automatically go to “SPEED SELECTION”

SPEED SELECTION

The speed selection menu for the operating speed is now 

activated and is identified by 

.

-   Press the 

 ▲

 or 

 ▼

 

button to select the ventilation 

speeds: MAX/MED or MIN, the selected speed value will flash. 

-   Press the 

OK

 button to select the desired speed. The wall 

control will automatically go to “ECONO MODE”.

ECONO MODE

The econo mode is now activated and is identified by  .
-   Press the 

 ▲

 or 

 ▼

 button to enable or disable the 

ECONO mode option, the selected 

 mode value will flash. 

-   Press the 

OK

 button to select the desired econo mode. 

The wall control returns to the selected operating mode.

RECIRCULATION MODE  

(Only available on selected models)

To enable or disable the RECIRC mode option.
-   Press and hold simultaneously the 

OK

 and 

 ▼

  

buttons for 3 seconds will enable the RECIRC mode feature 

and is identified by  .

-   Press the 

 ▲

 or 

 ▼

  button to enable or disable the 

RECIRC mode, the selected RECIRC value will flash.  

-  Press the 

OK

 button to select the desired RECIRC mode. 

(RECIRC only compatible with C 3.14, RNC 1.0 and XDH 7.15 

models.)

 The wall control returns to the selected operating 

mode.

SETTING THE RELATIVE HUMIDTY (RH) LEVEL.

Setting the relative humidity (RH) for the desired indoor humidity 

level (in percentage). This value will be used to boost the 

ventilation system to maximum speed based on the measured 

indoor relative humidity value. 
-   Press and hold simultaneously the 

OK

 and  

 ▲

 

buttons to for 3 seconds. The relative humidity percentage 

value will flash. (Default setting = 80%). 

-   Press the 

 ▲

 or 

 ▼

   button to change the value. (Value 

changes by 1% increments). Lower value 20%/Higher value 80%. 

-   Press the 

OK

 button to select the desired relative humidity 

(RH). The wall control will automatically go to “SUMMER MODE”.

IMPORTANT:

   = Relative humidity (RH) is below 20% 

 

 = Relative humidity (RH) is above 80%

SUMMER MODE:

The summer mode offers a simple way to maximize your indoor 

air quality comfort during the summer months.
-   Press the 

 ▲

 or 

 ▼

 buttons to enable or disable the 

summer mode feature, it will be identified by  . The selected 

SUMMER value will flash.

-   Press 

OK

 button to select the desired summer mode.  

The wall control returns to the selected operating mode.

ENABLE OR DISABLE THE BACKLIGHT

-   Press and hold simultaneously the 

 ▲

 and 

 ▼

 buttons 

for 3 seconds, to enable or disable the LCD display backlight, 

the display will flash to identify the desired selection.  

(Default mode = LCD backlight is disabled)

IMPORTANT:

: A wait time of 10 seconds is required to 

fully disable or enable the LCD display backlight. 

Note:

 Pressing the 

 ▲

 or 

 ▼

 button will illuminate to 

the backlight, it remains illuminated for a period of 10 seconds 

after the last button is pressed (no matter the button)

FACTORY RESET PROCEDURE:

-  Press and hold simultaneously the 

 ▲

OK

 and 

 ▼

 

buttons for 5 seconds. 

Note:

 The factory default value after reset = "OFF"

-  Unplug the ventilation system from the power source for a 

period of 30 seconds.

-  Proceed and plug in the ventilation system back into the 

power source. Proceed to power ON the wall control.

INSTALLATION AND OWNERS GUIDE

      

VENTILATION

PREF

ECONO

VENT

20 MIN/HR

OFF

ON/OFF

OFF

VENT

RECIRC

20 MIN/HR  

SUMMER/ÉTÉ

88

%

MED

MIN

MAX

      

VENTILATION

PREF

ECONO

VENT

20 MIN/HR

OFF

ON/OFF

OFF

VENT

RECIRC

20 MIN/HR  

SUMMER/ÉTÉ

88

%

MED

MIN

MAX

1

/

4

"

1

/

4

"

Wall Plate

Control

Switch

Junction Box

Wall

1

/

4

 po

1

/

4

 po

Plaque

murale

Commande

murale 

Boîte 

de jonction

Mur

B

INTERLOCK

COM

N.O.

N.C.

RLY1

4321

D1

SW3

TIMER

REMOTE

W

R

B1

G

W

B1

G

R

G

B

R

MASTER

PROG

J2

+

Fig. 1.0 Wiring diagram

Control Switch 

Ventilation System

POWER FAILURE:

After a power failure, the wall control returns to its original selected operating mode. All settings are kept in memory.

WALL CONTROL COMPATIBILITY

Due to constant product evolution and updated technologies, some wall controls are not compatible with earlier ventilation system 

models. For more details please contact our technical support line at 888.724.5211 our via e-mail [email protected].

Greentek

50 Kanalflakt Way,  

Bouctouche, NB  Canada    E4S 3M5
Toll free: 1 888 724-5211      

Fax: 1 (866) 426-7430 
Visit us at: www.greentek.ca 