VECTRA SERIES
IMPORTANT SAFETY INSTRUCTIONS
WARNING
– ALWAYS DISCONNECT THE UNIT
BEFORE PERFORMING MAINTENANCE OR
MAKING ANY CONNECTIONS. FAILURE TO
DISCONNECT POWER COULD RESULT IN ELECTRICAL
SHOCK OR DAMAGE, TO THE WALL CONTROL OR THE
ELECTRONIC COMPONENTS. IT IS RECOMMENDED
TO WEAR SAFETY GLASSES AND GLOVES WHILE
PERFORMING THESE INSTRUCTIONS.
CAUTION
– FOLLOW THE INSTRUCTION TO INSURE
PROPER OPERATION AND FUNCTIONALITY OF THE
CONTROL AND VENTILATION SYSTEM. – ONLY
ONE WALL CONTROL PER VENTILATION SYSTEM IS
POSSIBLE - KEEP WALL CONTROL LOW VOLTAGE WIRES
MINIMUM 2FEET(610MM) AWAY FROM MOTORS, LIGHT
BALLAST, DIMMERS AND ELECTRICAL PANELS – DO
NOT ROUTE WALL CONTROL LOW VOLTAGE WIRES
ALONG SIDE HIGH VOLTAGE WIRES – MINIMUM WIRE
REQUIREMENTS: LVT 18/4 CSA/UL. – THE DEFINED
MAXIMUM LENGTH FOR THE WIRE CONNECTION IS
250 FT (MAX).
MOUNTING THE VECTRA SERIES WALL
CONTROLS (EHC 1.0 TC AND EHC 1.5 DC)
1) Unplug the ventilation system from main power source.
2) Installation with a single electrical junction box. Find a suitable
location for the wall control that is free of obstructions. Using
the electrical junction box, outline the box on the wall. Proceed
to cut out the opening outlined on the wall.
3) Once the hole in the drywall is cut out, enter the wall control
routed wires from the unit through the circular opening of the
electrical junction box and push into place. Note: Always secure
the junction box to a wall stud or by using electrical junction box
side brackets. With a screw driver, secure the wall control wires
to the electrical junction box with the built in clamp.
Note:
The wall control can also be installed without
using a electrical junction box, by simply cutting a
2-7/8” by 1-1/3” at the desired location and securing it
to the wall with wall anchors.(included)
4) Remove the insulation covering the end of the wire to expose
the 4 wires, then strip the end of each individual wire. With
a screw driver connect each wire on the back of the control
switch to its corresponding terminal. RED wire to “R” / BLACK
wire to “B1” / GREEN wire to “G” and WHITE wire to “W”. (Ref
to figure 1.0)
5) Mount the wall control and install the Decora® wall plate.
6) Plug the ventilation system and proceed to test the wall control
operation.
OPERATING THE
VECTRA EHC 1.0 TC
WALL CONTROL
POWER ON/OFF WALL CONTROL
Press the button powers the wall control ON or OFF
Note:
The default mode when powered ON is “VENT”
VENTILATION MODE SELECTION
Press the
button is the ventilation mode selector for your
ventilation system, when the control is powered ON,
= Friendly continuous ventilation energy savings
mode
= Continuous ventilation mode maximizes your
indoor air quality
= 20 min maximum speed / 40 min intermittent
(the ventilation system is in stand-by mode)
= The ventilation system is powered OFF. (puts the
unit in stand-by mode), it will respond to override
controls. (If present)
OPERATING THE
VECTRA EHC 1.5 DC
WALL CONTROL
= Continuous ventilation mode maximizes
your indoor air quality
= Friendly continuous ventilation energy
savings mode
= Recirculation ventilation mode (compatible
with SS3.12 DD, DH 7.15 and XDH 7.15 only)
= 20 min continuous ventilation /
40 min intermittent (standby) mode
= 20 min continuous ventilation /
40 min recirculation mode
= Humidistat override mode
= Maximum ventilation speed
= Medium ventilation speed
= Minimum ventilation speed
= The ventilation system is powered OFF.
(puts the unit in stand-by mode), it will
respond to override controls. (If present)
POWER ON/OFF WALL CONTROL
- Press and hold the
OK
button for 3 seconds to power
“ON” the wall control.
Note:
The factory default values are: “VENT MODE /
MED SPEED”
- Press and hold the
OK
button for 3 seconds to power
“OFF” the wall control.
VENTILATION MODE SELECTION
- Press the
OK
button to enable the selection menu for the
ventilation operating mode.
- Press the
▲
or
▼
button to select the ventilation
modes: VENT - 20MIN/HR – RECIRC or RECIRC-20 MIN/HR
the selected ventilation mode value will flash.
- Press the
OK
button to select the desired ventilation mode.
The wall control will automatically go to “SPEED SELECTION”
SPEED SELECTION
The speed selection menu for the operating speed is now
activated and is identified by
.
- Press the
▲
or
▼
button to select the ventilation
speeds: MAX/MED or MIN, the selected speed value will flash.
- Press the
OK
button to select the desired speed. The wall
control will automatically go to “ECONO MODE”.
ECONO MODE
The econo mode is now activated and is identified by .
- Press the
▲
or
▼
button to enable or disable the
ECONO mode option, the selected
mode value will flash.
- Press the
OK
button to select the desired econo mode.
The wall control returns to the selected operating mode.
RECIRCULATION MODE
(Only available on selected models)
To enable or disable the RECIRC mode option.
- Press and hold simultaneously the
OK
and
▼
buttons for 3 seconds will enable the RECIRC mode feature
and is identified by .
- Press the
▲
or
▼
button to enable or disable the
RECIRC mode, the selected RECIRC value will flash.
- Press the
OK
button to select the desired RECIRC mode.
(RECIRC only compatible with C 3.14, RNC 1.0 and XDH 7.15
models.)
The wall control returns to the selected operating
mode.
SETTING THE RELATIVE HUMIDTY (RH) LEVEL.
Setting the relative humidity (RH) for the desired indoor humidity
level (in percentage). This value will be used to boost the
ventilation system to maximum speed based on the measured
indoor relative humidity value.
- Press and hold simultaneously the
OK
and
▲
buttons to for 3 seconds. The relative humidity percentage
value will flash. (Default setting = 80%).
- Press the
▲
or
▼
button to change the value. (Value
changes by 1% increments). Lower value 20%/Higher value 80%.
- Press the
OK
button to select the desired relative humidity
(RH). The wall control will automatically go to “SUMMER MODE”.
IMPORTANT:
= Relative humidity (RH) is below 20%
= Relative humidity (RH) is above 80%
SUMMER MODE:
The summer mode offers a simple way to maximize your indoor
air quality comfort during the summer months.
- Press the
▲
or
▼
buttons to enable or disable the
summer mode feature, it will be identified by . The selected
SUMMER value will flash.
- Press
OK
button to select the desired summer mode.
The wall control returns to the selected operating mode.
ENABLE OR DISABLE THE BACKLIGHT
- Press and hold simultaneously the
▲
and
▼
buttons
for 3 seconds, to enable or disable the LCD display backlight,
the display will flash to identify the desired selection.
(Default mode = LCD backlight is disabled)
IMPORTANT:
: A wait time of 10 seconds is required to
fully disable or enable the LCD display backlight.
Note:
Pressing the
▲
or
▼
button will illuminate to
the backlight, it remains illuminated for a period of 10 seconds
after the last button is pressed (no matter the button)
FACTORY RESET PROCEDURE:
- Press and hold simultaneously the
▲
,
OK
and
▼
buttons for 5 seconds.
Note:
The factory default value after reset = "OFF"
- Unplug the ventilation system from the power source for a
period of 30 seconds.
- Proceed and plug in the ventilation system back into the
power source. Proceed to power ON the wall control.
INSTALLATION AND OWNERS GUIDE
VENTILATION
PREF
ECONO
VENT
20 MIN/HR
OFF
ON/OFF
OFF
VENT
RECIRC
20 MIN/HR
SUMMER/ÉTÉ
88
%
MED
MIN
MAX
VENTILATION
PREF
ECONO
VENT
20 MIN/HR
OFF
ON/OFF
OFF
VENT
RECIRC
20 MIN/HR
SUMMER/ÉTÉ
88
%
MED
MIN
MAX
3
1
/
4
"
2
1
/
4
"
Wall Plate
Control
Switch
Junction Box
Wall
3
1
/
4
po
2
1
/
4
po
Plaque
murale
Commande
murale
Boîte
de jonction
Mur
B
INTERLOCK
COM
N.O.
N.C.
RLY1
4321
D1
SW3
TIMER
REMOTE
W
R
B1
G
W
B1
G
R
G
B
R
MASTER
PROG
J2
–
+
Fig. 1.0 Wiring diagram
Control Switch
Ventilation System
POWER FAILURE:
After a power failure, the wall control returns to its original selected operating mode. All settings are kept in memory.
WALL CONTROL COMPATIBILITY
Due to constant product evolution and updated technologies, some wall controls are not compatible with earlier ventilation system
models. For more details please contact our technical support line at 888.724.5211 our via e-mail [email protected].