Greenlee CM-600 Instruction Manual Download Page 1

INSTRUCTION MANUAL

Read

 and 

understand

 all of the instructions and safety information in this 

manual before operating or servicing this tool.

CM-600 • CM-650

Clamp-on Meters

99945550 

© 2008 Greenlee Textron Inc.  IM 1520 REV 2  10/08

Summary of Contents for CM-600

Page 1: ...ANUAL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool CM 600 CM 650 Clamp on Meters 99945550 2008 Greenlee Textron Inc IM 1520...

Page 2: ...tion provided Purpose of This Manual This instruction manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the Greenlee CM 600 and CM 650 Clamp on Met...

Page 3: ...reventing or avoiding the hazard Immediate hazards which if not avoided WILL result in severe injury or death Hazards which if not avoided COULD result in severe injury or death Hazards or unsafe prac...

Page 4: ...it for the manufacturer s intended purpose only as described in this manual Any other use can impair the protection provided by the unit Failure to observe these warnings could result in severe injury...

Page 5: ...able or inaccurate readings Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not change the measurement function while the test leads are connected to...

Page 6: ...l 7 V terminal 8 Battery Cover 9 Battery Cover Screw Symbols on the Unit Warning Read the instruction manual Double insulation Battery 5 6 4 2 1 7 3 9 8 Front Back Display Icons 10 Hold function is en...

Page 7: ...ing method uses internal circuitry to read the true RMS value This method is accurate within the specified crest factor limitations whether the input signal is a pure sine wave a square wave sawtooth...

Page 8: ...specific measurement instructions 3 Test the unit on a known functioning circuit or component If the unit does not function as expected on a known functioning circuit replace the battery If the unit s...

Page 9: ...y Close the jaw completely Center the wire in the jaw for highest accuracy Clamp Around Line Splitter Notes The Greenlee 93 30 Line Splitter is divided One section renders amps the other renders amps...

Page 10: ...0 Hz N A AC Current 600 A range 0 to 400 A 1 5 5 A 50 60 Hz N A 400 to 600 A 2 5 5 A 50 60 Hz Resistance 0 to 2000 1 5 2 N A N A Maximum open circuit voltage 1 V Continuity Threshold Tone sounds if th...

Page 11: ...humidity Remove battery Indoor use only Altitude 2000 m 6500 maximum Pollution Degree 2 Battery 9 Volt battery NEDA 1604 JIS 006P or IEC 6LF22 Battery Replacement Electric shock hazard Before opening...

Page 12: ...Customer Service at 800 435 0786 and request a Return Authorization For items not covered under warranty such as items dropped abused etc a repair cost quote is available upon request Note Prior to r...